Operation Manual

30
Dear Customer
With the purchase of a DR. KERN tanning system you
made the decision to own a technically high quality
and high performance unit. During the manufacturing
of the unit we have done everything to warrant a defect-
free and safe tanning experience.
Besides you can contribute to the fact that you are going
to be satisfied with your equipment for a long time.
Please read the operating instructions carefully and
handle the assembly according to the enclosed
assembly manual.
Only a professional assembly guaranties the
impeccable function of the tanner.
Important indications
ê Connection to a 380-400 V 3N AC (solid connection
with separator or CEE plug connection)
ê Use connection line H05W-5 FG 2,5²
ê Floor loading minimum 4,5 KN/m²
With lower loading capacity the installer must show
a respective proof.
ê Installation in a dry room, protected from spray-water
and drip-water.
ê maximum relative humidity 70%
ê maximum room temperature 28°C
higher room temperature = higher temperature in
the tanning room
ê Do not cover air intake openings and warm air exit
openings at the cooling ventilator otherwise unit will
overheat
ê With ventilator failure resulting in overheating of the
unit, shut unit off immediately
ê Always disconnect the unit from the main power
when working on the tanning unit (lamp and starter
replacement or cleaning)
ê Have repair performed only by a locally licensed
electrician or by the factory service department
The equipment is shipped disassembled on one pallet.
The pallet contains:
4 radiation segments + 2 door segments
Floor plates, exhaust air unit, accessories and
assembly parts
Choice of location
The acrylic disks are not compatible with some
cosmetics and cleaning agents on the market. The
compatibility with our product ECOCLEAN have been
tested and can be applied without reservation.
We are not liable for damage to the acrylic disk by
chemical products of other manufacturers.
Attention!
This unit has an exhaust air system which only works
properly with an sufficient incoming and outgoing air.
The warranty expires if the requirements will not be
fulfilled.
Please note:
- Be sure there is enough space on location
for maneuvering the booth
Recommended minimum booth size without
use of the additional changing booth 3.4 m
2
Installation of the equipment should be on an level floor;
slight unevenness can be compensated for with leveling
legs.
Observe specification for electric and exhaust air
connection.
The electric connection may only be carried out
by a licensed specialist or a licensed electrician
under consideration of the regulations of the VDE
and the local EVU.
Before installation make sure that all parts have been
delivered without damage.
1 set of hex keys from 2 to 10 mm
1 slotted head screwdriver
1 Phillips head screwdriver
1 set of open-end wrenches
Required tools
english