Operation Manual

31
l Now adjust the air conditioning system in the correct
position.
l Use the appropriate feeder clamp of the control unit
for the electric connection (see fig. 17).
Here you need the enclosed connection cable.
l Now assemble the air hose at the front cover of the
cooler (fig. 34).
Fig. 34
front cover
l Assemble the cover of the top cooler (fig. 35).
Fig. 35
Assembly of air conditioning system
(optionally)
l First unscrew the posterior modesty panel of the
tanning segment (fig. 32).
l Then open the cover panel over the control unit
(fig. 33).
Fig. 32
Fig. 33
Each bend increases the air resistance in the hose. Ben-
ding by 180° should be avoided in any case. A hose of
the length of 2 m can be used without additional cooler
when laid straight. In the case of longer hoses and
bends an additional cooler is recommended to make
sure that the exhaust air can be removed without
problems. The diameter of the hose should never be
reduced as this may lead to an accumulation of air.
Height requirements:
l with straight upwards ducting: 2.75 m
l with horizontal ducting: 3.00 m
english