Operation Manual
Make sure that the individual ballast unit groups can
be removed from the module from above, which
simplifies transport.
Disassembly of the canopy
Pull the covers from the bearing point on both sides of
the system.
Then unscrew the threaded fasteners (2 x M10) per side.
Now remove the exhaust hoses on the rear side of the
canopy. To do so, loosen the hose clamps and pull the
hoses from the connecting struts in a downward motion.
ballast unit groups
ballast unit groups
27english
threaded fasteners M10
Canopy
hose clamps
exhaust hose
Canopy
In addition, the electrical cable connections from the
canopy to the base in the rear base wall must be
disassembled.
To this end, remove the threaded fasteners (Ø4.2 x 9.5)
on the mounting plates (2 each per mounting plate)
and pull the lines with the mounting plates towards the
rear and out.
mounting plate, left
threaded
fasteners
Ø 4,2 x 9,5
mounting plate, right
exhaust unit
connecting lines
control unit
connecting cable, canopy 2
main power
cable 5 x 2,5
2
connecting cable, canopy 1