Operation Manual
19
these screws solve (4x)
Servicing of the Face tanner
The face tanner bulb should also be serviced in regular
intervals. To do this, loosen the screws on the outer
frame of the face tanner
To change the metal-halogen-bulb, grasp only the flat
ends and press them into the spring-loaded lamp-
holders until properly secured. Ensure that the globe
envelope itself dies not come into contact with your
fingers. If this occurs, it should be cleaned with alcohol
or spirit before use.
lide the filter glasses out and clean them on a regular
basis. Make sure that the filter glasses are replaced in
the proper order, with the blue glass closest to the
facial bulb.
Facial bulbs operate at very high temperatures and are
cooled with a fan in the cassette. The bulb function is
controlled additionally by a heat sensor. Should the fan
stop working the relay will turn the face tanner off
automatically. The face tanner may not be used until
an authorised service representative has repaired the
problem. Automatic emergency shut-offs of this type
occur very infrequently. The cassette fan in the facial
tanner normally doer not fail.
Dont use the facetanner with defective filter disk.
The use with defective filter disk entails strong
skin burns.
FIG. 17
FIG. 18
these screws solve
(4x)
FIG 19
Thermal safety device
english