User Manual

Note: There may be a trace of smoke or odor when the unit is first operated.
Do not be alarmed. This indicates a drop of oil fell on the interior coils during
the manufacturing process. It will quickly evaporate and should not recur.
QUESTIONS AND ANSWERS
If the heater cycles ON/OFF without heating:
Please note: This is a smart heater that monitors the room temperature and
produces heat only when needed.
You can set the desired room temperature with the heater in either AUTO
HIGH or AUTO LOW mode. (The factory default setting is 68 °F.) For an
example of how the heater works, let’s say you set the temperature for 70 °F.
Once the room has reached 70 °F, the heater switches off and the fan stops
(Note: The heater remains on STANDBY as long as you do not POWER OFF).
As the heater remains on STANDBY, it will read the room temperature every 5
minutes by running the fan ONLY for 30 seconds. During this process, the fan
also blows out the residual heat from inside the chamber to ensure an
accurate temperature reading of the room. If the room temperature is at 70
°F(or higher), the heater will remain on STANDBY. It will repeat this sensing
cycle, reading the room temperature, every 5 minutes. However, if the room
temperature drops 2 degrees lower than the set temperature, the heating
function will turn the heater ON and the fan will blow warm air.
If the heater cycles but doesn’t produce heat for hours:
If the temperature is set lower than room temperature, the heater will perform
only the sensing cycle and the heater will not turn on in the heating function.
To have the heater turn on, always set the desired temperature higher (2°+)
than the room temperature, or manually select High or Low to have instant