Specification Sheet
Technical Data Sheet
Dräger PARAT 5500 Fire Escape Hood
05.2017-TechnicalDataSheet_PARAT5500_EN
3.1 Mechanical resistance
Shock proofed
10,000 impacts for entire device
Drop test
6 x 1.5m on smooth concrete surface (from different starting positions)
Packaging Stability
Firing pin test acc. to EN 403:2004
Flame resistance
The unit does not contain easily flammable parts. At 800 ± 50°C the
device is pulled through an open flame at 6 ± 0.5 cm/sec. – when re-
moved from the flame, the device stops burning (self-extinguishing).
Temperature changing resistance
Performing in the listed order:
(70 ± 3) °C, rel. humidity < 20 %, (72 ± 3) h
(70 ± 3) °C, rel. humidity ≥ 95 %, (72 ± 3) h
(-30 ± 3) °C, (24 ± 1) h
Pressure changing
2 compressed air cycles with (-400 ±10) mbar for 60 sec
pressure compensation after < 20 sec.
3000 compressed air cycles with ( -300 ± 10) mbar for 60 sec.
pressure compensation after < 10 sec.
3.2 Particle filtration efficiency
(according to EN 143:2007 (P2))
Test Aerosols:
minimum efficiency
at a flow of 95 L/min
sodium chloride, paraffin oil
94 % NaCI, 94 % paraffin oil
3.3 Gas filtration capacity
Test conditions (EN 403:2004):
20x1,5 L sinus, 90 % rel. humidity, 25°C (CO)
30 L/min, 70 % rel. humidity, 20°C (Acrolein,HCI, HCN)
Test Gas
Concentration /
ppm
Breakthrough /
ppm
Minimum break-
through time /
min
CO 2,500
1)
200
2)
15
Acrolein 100 0.5 15
HCI 1,000 5 15
HCN 400 10 15
1)
Additional tests with 5,000, 7,500 and 10,000 ppm
2)
temporal weighted arithmetic mean during every 5 minutes
Test conditions (according to DIN 58647-7:1997):
30 L/min, 70% rel. humidity, 20°C
Test Gas
Concentration /
ppm
Breakthrough /
ppm
Minimum
breakthrough
time / min
H
2
S 2,500 10 15
3.4
Breathing resistance
(in acc. with EN 403:2004)
inhalation resistance:
< 8 mbar
exhalation resistance:
< 3 mbar