How to use these Instructions for Use
The header line ...
specifies the subject of the main chapter.
It is followed by the title of the sub-chapter – to help you find
your way rapidly around the manual.
The page body ...
contains the instructions for use
in a combination of text and illustrations. The information is
expressed directly in terms of actions which enable users to
familiarise themselves with the operation of the machine by
hands-on activity.
The left-hand column ...
contains the text
which provides explanations and guides the user with brief
and clear instructions in an ergonomic sequence for confusion
free use of the machine.
Bullet points indicate the working steps, numbers are used to
highlight the relation between the working step described, the
associated illustration(s) and the sequence of operations.
The right-hand column ...
contains the illustration(s)
which directly relate to the text opposite and show the user
where to find the items concerned. The focus is on the
elements mentioned in the text. Non-essentials are omitted.
Screen dumps are also used to guide the user and confirm the
working steps.
Preparation
20
Charging the battery
The ambient temperature must be between 0 and 35
o
C
when charging the batteries!
When the external supply is available:
1 the green lamp » N «, lights up regardless of whether the
ventilator is switched on or off. The battery is being
charged.
2 The three-coloured indicator »
J « lights up to show the
momentary charge status of the battery:
yellow: while the battery is still being charged,
green: when the battery has been fully charged,
red: if a serviceable battery has not been inserted or
cannot be charged, for instance because the
ventilator is being used outside the temperature
range from 0 to 35
o
C.
Indicators »
N « and » J « remain off while the ventilator is
being operated from the internal battery.
An Oxylog 3000 charging station connected to the mains
supply can be used to charge the battery externally, see "Order
List", page 102.
Refer to the manufacturer's technical specifications for
further information on the charging and discharging
characteristics (e.g. memory effect) of the battery used.
Indication of battery capacity / battery operation
3 The current capacity of the battery is indicated by
Oxylog 3000 in 25% increments in the bottom right-hand
line of the information window when switched on:
when charging from an external power supply,
as the battery is discharged during operation.
Example: 75 % charge
The accuracy of the capacity indication can vary, depending on
the age and degree of use of the battery, see "Technical Data",
page 90.
The capacity indication is overwritten if other, more important
messages have to be displayed on the ventilator.
Additional alarms draw attention to the remaining operating
time of the battery.
When operated via the rechargeable battery, the brightness of
the ventilator screen is reduced in order to save power.
The screen brightness is automatically increased to maximum
for one minute while settings are being made.
02437170
Oxylog 3000
1
2
05737171
This "Instructions for Use" manual is published for public use and is only meant for your information.
We do not guarantee the accuracy of these instructions with respect to your specific device type or status.
Only the "Instructions for Use" manual delivered together with a device is officially published for the use of that specific device.