Operating Instructions and Installation Instructions
Appendix 1: Technical data
Model 45M 45M 45M 45C
Nominal output 9 kW 9 kW 9 kW 9 kW
Flue connection (diameter) 150 mm 150 mm 150 mm 150 mm
Weight 155 kg 155 kg 155 kg 160 kg
Recommended fuel Wood Coal Brown coal Coal
Fuel property, max. length wood 45 cm 12/22 - 20/30 3" - 6" - 7" 12/22 - 20/30
Mass flow of flue gasses 8.5 g/s 7.6 g/s 8.8 g/s 7.6 g/s
Temperature increase measured in the
measuring section
273 °C 282 °C 286 °C 282 °C
Temperature measured at appliance
exit
410 °C 389 °C 395 °C 389 °C
Minimum draught 12 Pa 12 Pa 12 Pa 12 Pa
CO emission (13%O
2
) 0.09% 0.08% 0.07% 0.09%
NOx emission (13% O
2
) 60 mg/Nm³ - - -
CnHm emission (13%O
2
) 96 mg/Nm³ 136 mg/Nm³ 109 mg/Nm³ 136 mg/Nm³
Particulate emission 13 mg/Nm³ <40 mg/Nm³ 12.3 mg/Nm³ <40 mg/Nm³
Particulate emission in accordance
with NS3058-NS3059
- - - -
Efficiency 75.30% 79.50% 75% 79.50%
Model 55M 55M 55M 55C
Nominal output 9 kW 9 kW 9 kW 9 kW
Flue connection (diameter) 150 mm 150 mm 150 mm 150 mm
Weight 155 kg 155 kg 155 kg 160 kg
Recommended fuel Wood Coal Brown coal Coal
Fuel property, max. length wood 45 cm 12/22 - 20/30 3" - 6" - 7" 12/22 - 20/30
Mass flow of flue gasses 8.5 g/s 7.6 g/s 8.8 g/s 7.6 g/s
Temperature increase measured in the
measuring section
273 °C 282 °C 286 °C 282 °C
Temperature measured at appliance
exit
410 °C 389 °C 395 °C 389 °C
Subject to change because of technical improvements
23