9. Declared performance:
The harmonised norm EN 13240 :2001/A2 :2004/AC :2007
Essential characteristics Coal Performance
Fire safety
Fire resistance A1
Distance from combustible material
Minimum distance in mm
Rear: 400 with insulation
Side: 450 with insulation
Risk of glowing particles falling out Conform
Emission of combustion products CO: 0.08% (13%O2)
Surface temperature Conform
Electrical safety -
Ease of cleaning Conform
Maximum operating pressure -
Flue gas temperature at nominal output 282 °C
Mechanical resistance (carrying weight of chimney) Not determined
Nominal output 9 kW
Efficiency 79.5%