9. Declared performance:
The harmonised norm EN 13240 :2001/A2 :2004/AC :2007
Essential characteristics Wood | Coal | Brown coal
Fire safety
Fire resistance A1
Distance from combustible material
Minimum distance in mm
Rear: 300
Side: 450
Risk of glowing particles falling out Conform
Emission of combustion products
CO: 0.09% (13%O2) | CO: 0.08% (13%O2)|
CO: 0.07% (13%O2)
Surface temperature Conform
Electrical safety -
Ease of cleaning Conform
Maximum operating pressure -
Flue gas temperature at nominal output 27C | 28C |28C
Mechanical resistance (carrying weight of chimney) Not determined
Nominal output 9 kW
Efficiency 75.3% | 79.5% | 75%
10. The performance of the product described in points 1 and 2 conform with the performance reported
in point 9.
This performance declaration is supplied under the exclusive responsibility of the producer specified
in point 4:
01/09/2014 Weelde
Tom Gehem
CEO
Due to continuous product improvement, the supplied appliance specifications may vary from the description in
this brochure without prior notice having been given.