Vintage Series Insstructions
Appendix 1: Technical data
Model Vintage 50 Vintage 35 Vintage 30
Nominal output 9 kW 7 kW 5 kW
Flue connection (diameter) 150 mm 150 mm 150 mm
Weight +/- 155 kg +/- 125 kg +/- 95 kg
Recommended fuel Wood Wood Wood
Fuel property, max. length 50 cm 35 cm 30 cm
Mass flow of flue gases 6.4 g/s 4.9 g/s 4.2 g/s
Flue gas temperature measured in the
measurement section
232 251 244
Temperature measured downstream from the flue
spigot
328 298 305
Minimum draught 12 Pa 12 Pa 12 Pa
CO emission (13%O2) 0,10 % 0,05 % 0,05 %
NOx emission (13% O2) 112 mg/Nm³ 84 mg/Nm³ 127 mg/Nm³
CnHm emission (13%O2) 96 mg/Nm³ 82 mg/Nm³ 48 mg/Nm³
Particulate emission 27.1 mg/Nm³
16.4
mg/Nm³
6.0 mg/Nm³
Particulate emission in accordance with NS3058-
NS3059
4.94 gr/kg 4,99 gr/kg 1.38 gr/kg
Efficiency 84,2 % 83 % 80,4 %
Subject to change because of technical improvements
19