9. Declared performance:
The harmonised norm EN 13240:2001/A2 ;2004/AC :2007
Essential characteristics Performance Wood
Fire safety
Fire resistance A1
Distance from combustible material
Minimum distance in mm
Rear: 300
Side: 500
Risk of glowing particles falling out Conform
Emission of combustion products CO: 0.18% (13%O
2
)
Surface temperature Conform
Electrical safety -
Ease of cleaning Conform
Maximum operating pressure -
Flue gas temperature at nominal output 247
Mechanical resistance (carrying weight of chimney) Not determined
Nominal output 4.9 kW
Efficiency 79.5%
10. The performance of the product described in points 1 and 2 conform with the performance reported
in point 9.
This performance declaration is supplied under the exclusive responsibility of the producer specified
in point 4:
01/10/2013 Weelde
Tom Gehem
CEO
Due to continuous product improvement, the specifications of the appliance supplied can vary from the descrip-
tion in this brochure without prior notice.
DOVRE N.V.
Nijverheidsstraat 18 Tel : +32 (0) 14 65 91 91
B-2381 Weelde Fax : +32 (0) 14 65 90 09
Belgium E-mail : info@dovre.be
Subject to change because of technical improvements
5