INSTALLATIEVOORSCHRIFTEN EN GEBRUIKSAANWIJZING INSTALLATION INSTRUCTIONS AND OPERATING MANUAL INSTALLATION ET MODE D’EMPLOI EINBAUANLEITUNG UND GEBRAUCHSANWEISUNG INSTRUCCIONES DE INSTALACIÓN Y USO REQUISITI PER L'INSTALLAZIONE E ISTRUZIONI PER L'USO MONTERINGS- OG BRUKSANVISNING HOUTKACHEL WOOD STOVE POELE A BOIS HOLZ-FEUERSTÄTTE ESTUFA DE LEÑA STUFA A LEGNA ILDSTED Sense 100 Sense 103/113 Sense 200 Sense 203 Sense 300 Sense 303 Sense 400 Sense 403 Sense 03.27127.
Table of contents 2 Introduction 3 Performance declaration 4 Performance declaration 6 Performance declaration 8 Safety 10 Installation requirements General Flue Room ventilation Floor and walls Product description 10 10 10 11 11 12 Installation General preparation Preparing the connection to the flue Preparing the outside air connection Installing and connecting 13 13 14 15 15 Use First use Fuel Lighting Burning wood Controlling combustion air Extinguishing the fire Removing ash Fog and mis
Introduction Dear user, By purchasing this heating appliance from DOVRE you have selected a quality product. This product is part of a new generation of energy-efficient and environmentally-friendly heating appliances. These appliances make optimal use of convection heat as well as thermal radiation (radiant heat). Your DOVRE appliance has been manufactured with state-of-the-art production equipment. In the unlikely event of a malfunction, you can always rely on DOVRE for support and service.
Performance declaration In accordance with construction products regulation 305/2011 No. 033-CPR-2013 1. Unique identification code of the product type: Sense 100 - 200 / 4.9 kW 2. Type, batch or serial number or other form of identification for the construction product, as prescribed in article 11, subsection 4: Unique serial number. 3.
9. Declared performance: The harmonised norm EN 13240:2001/A2 ;2004/AC :2007 Essential characteristics Performance Wood Fire safety Fire resistance A1 Distance from combustible material Minimum distance in mm Rear: 300 Side: 500 Risk of glowing particles falling out Conform Emission of combustion products CO: 0.
Performance declaration In accordance with construction products regulation 305/2011 No. 032-CPR-2013 1. Unique identification code of the product type: Sense 100 - 200 / 7 kW 2. Type, batch or serial number or other form of identification for the construction product, as prescribed in article 11, subsection 4: Unique serial number. 3.
9. Declared performance: The harmonised norm EN 13240:2001/A2 ;2004/AC :2007 Essential characteristics Performance Wood Fire safety Fire resistance A1 Distance from combustible material Minimum distance in mm Rear: 300 Side: 500 Risk of glowing particles falling out Conform Emission of combustion products CO: 0.
Performance declaration In accordance with construction products regulation 305/2011 No. 041-CPR-2014 1. Unique identification number of the product type: Sense 300 - 400 / 9 kW 2. Type, batch or serial number or other form of identification for the construction product, as prescribed in article 11, subsection 4: Unique serial number. 3.
. Declared performance: The harmonised norm EN 13240:2001/A2 ;2004/AC :2007 Essential characteristics Performance Wood Fire safety Fire resistance A1 Distance from combustible material Minimum distance in mm Rear: 400 Side: 500 Risk of glowing particles falling out Conform Emission of combustion products CO: 0.
Safety Please note: All safety regulations must be complied with strictly. Please read carefully the instructions supplied with the appliance for installation, use and maintenance before using the appliance. The appliance must be installed in accordance with the legislation and requirements applicable in your country. All local regulations and the regulations relating to national and European standards must be observed when installing the appliance.
The flue must satisfy the following requirements: The flue or chimney must be made of fire-resistant material, preferably ceramics or stainless steel. The flue or chimney must be airtight and wellcleaned and guarantee sufficient draught. A draught/vacuum of 15 - 20 Pa during normal operation is ideal. Starting from the flue spigot, the flue must run as vertically as possible. Changes in direction and horizontal pieces disrupt the outward flow of combustion gases and may cause soot deposits.
the appendix "Distance from combustible material". Product description Remove combustible material such as linoleum, carpets/rugs and similar materials below the fireproof protective plate. Keep sufficient distance between the appliance and combustible materials such as wooden walls and furniture. The connecting tube also radiates heat. Ensure that there is sufficient distance or a shield between the connecting tube and combustible material.
Door lock 1. Open the door; see the following figure: The appliance is supplied with the latch button (4) installed. The door is opened by pressing in the latch button. As the latch button becomes warm during use, a glove has been supplied which you can use to protect your hand. Installation General preparation Please check the appliance immediately after delivery for damage during transport or any other damage or defects. The appliance is attached to the pallet with screws at the bottom.
1 09-20021-014 01 02 03 04 05 06 07 08 09 10 11 12 Removable internal parts fire compartment base fire basket right rear fire basket left rear fire basket right fire basket left fire basket side inner plate right rear side inner plate left rear baffle plate inner plate side inner plate right side inner plate left ash pan Fitting the heat shield To fit the optional heat shield, proceed as follows: 1. Screw 2 M6 studs (1) with spacer (2) to the rear wall. 2.
2 2 1 1 09-20021-015 Connecting to the rear For a connection to the rear, the position of the connection collar needs to be changed. The connection collar is attached with 2 M8 nuts (key 13). Proceed as follows: 1. First remove the baffle plate. 2. Unscrew the nuts and remove the connection collar. Check that the sealing tape on the contact surface is not damaged. Replace the sealing tape if it is damaged. 3. Place the connection collar turned 180° with respect to its original position; see next figure.
Use First use When you use the appliance for the first time, make an intense fire and keep it going for a good few hours. This will cure the heat-resistant paint finish. This may result in some smoke and odours. You could open windows and doors for a while in the area in which the appliance is located. Fuel 1 09-20021-017 2. If the appliance is to be placed on a smooth floor, the four anti-slip pads can be placed beneath the adjustable feet to prevent the appliance from moving, see next image.
water vapour will condense in the appliance and can leak away through chinks in the stove, causing black stains on the floor. It may also condense in the chimney and form creosote. Creosote is a highly flammable compound and may cause a chimney fire. Lighting You can check whether the flue has sufficient draught by lighting a ball of paper above the baffle plate. A cold flue often has insufficient draught and consequently, some smoke may escape into the room instead of up the chimney.
Open stacking Controlling combustion air The appliance has various features for air control; see next figure. The appliance has one air slide that regulates both the primary air and the secondary air inlet. If the air slide is completely pulled out, the primary and the secondary air inlet is open. As the air slide is pushed in, the primary air inlet and then the secondary air inlet is closed.
Advice accumulate behind a cast-iron inner plate. Remove the excess ash regularly. Never burn wood with an open door. Regularly burn wood with intense roaring fires. If you burn at a low setting frequently, tar and creosote may be deposited in the flue. Tar and creosote are highly combustible substances. Thicker layers of these substances may catch fire if the temperature in the flue increases suddenly. By allowing the fire to burn very intensely regularly, layers of tar and creosote will disappear.
Maintenance Follow the maintenance instructions in this chapter to keep the appliance in good condition. Flue In many countries, you are required by law to have your chimney checked and maintained. At the start of the heating season: have the chimney swept by a recognised chimney sweep. During the heating season and after the chimney has not been used for a long time: have the chimney checked for soot. At the end of the heating season: close off the chimney and plug with newspaper.
kettle directly onto an enamelled stove; use a stand to prevent damage. Attention: Do not allow aggressive acidic products to get onto enamelled components. Lubrication Although cast-iron is slightly self-lubricating, you will still need to lubricate moving parts frequently. Lubricate the moving parts (such as guide systems,hinge pins, latches and air slides) with heat resistant grease that is available in the specialist trade.
is used again. Sense spare parts In order to replace the side glass, all the inner panels and the air guide must first be removed. The air guide is attached with a M8 nut in the middle at the top of the appliance. Proceed as follows: 1. Unscrew the two glass fixings with parts (1) and (2) and remove the glass (3), see following figure. 2. Check the glass seal and, if necessary, fit a new sealing rope. 3. Place the new glass in the grove and tighten the glass fixings. 1 Sense 100/103/113/200/203 2 Pos.
06 03.77440.002 fire basket 07 03.77548.000 side inner plate right rear 08 03.77547.000 side inner plate left rear 09 03.76188.000 baffle plate inner plate 10 03.77550.000 side inner plate right 11 03.77549.002 side inner plate left 12 03.05216.
Appendix 1: Technical data Model Sense 100/103/113/ 200/203 Sense 100/103/113/ 200/203 Sense 300/303/ 400/403 Nominal output 4.9 kW 7.0 kW 9.0 kW Flue connection (diameter) 150 mm 150 mm 150 mm Weight 105 kg - 125 kg 105 kg - 125 kg 150 kg - 180 kg Recommended fuel Wood Wood Wood Fuel property, max. length 33 cm 33 cm 40 cm Mass flow of flue gasses 4.5 g/s 5.1 g/s 7.
Appendix 2: Dimensions Sense 100 360 100 375 150 100 285 300 790 900 150 470 09-20021-001 Subject to change because of technical improvements 25
Sense 103 360 100 375 150 100 285 300 790 900 150 470 09-20021-002 26 Subject to change because of technical improvements
Sense 113 100 360 120 105 610 720 150 470 375 100 150 09-20021-034 Subject to change because of technical improvements 27
Sense 200 360 375 150 100 365 380 870 980 100 150 470 09-20021-003 28 Subject to change because of technical improvements
Sense 203 360 375 150 100 365 380 870 980 100 150 470 09-20021-004 Subject to change because of technical improvements 29
Sense 300 425 440 150 115 340 355 100 930 1060 150 555 09-20021-005 30 Subject to change because of technical improvements
Sense 303 555 100 440 150 115 340 355 930 1060 150 425 09-20021-006 Subject to change because of technical improvements 31
Sense 400 555 440 150 115 430 450 1025 100 1160 150 425 09-20021-007 32 Subject to change because of technical improvements
Sense 403 425 440 150 115 430 450 1025 100 1160 150 555 09-20021-008 Subject to change because of technical improvements 33
Appendix 3: Distance from combustible material Sense 100/103/113/200/203 4.
Sense 100/103/113/200/203 4.
Sense 300/303/400/403 - 9 kW - Minimum distances in millimetres for version without heat shield 1100 890 100 300 100 1 2 150 1050 150/100* * with/without sideglass 1 Combustible material 2 Incombustible material, thickness 100 mm 1050 150/100* 1120 500/300* 1120 500/300* 100 1100 150 150/100* 500 930 100 1180 300 1050 150/100* 09-20021-031 Please note: In order to guarantee the supply of combustion air when there is no outside air supply connection, the distance from the connec
Sense 300/303/400/403 - 9 kW - Minimum distances in millimetres for version with heat shield * with/without sideglass 1 Combustible material 2 Incombustible material, thickness 100 mm 1 2 09-20021-032 Please note: In order to guarantee the supply of combustion air when there is no outside air sup
Sense - Dimensions of fireproof floor plate B A B 09-20021-030 Minimum dimensions of fireproof floor plate A (mm) B (mm) Din 18891 500 300 Germany 500 300 Finland 400 100 Norway 300 5 38 Subject to change because of technical improvements
Appendix 4: Diagnosis diagram Problem Wood will not stay lit Gives off insufficient heat Smoke emissions into the room when adding wood Fire in appliance is too intense, is hard to adjust Deposit on the glass possible cause possible solution Insufficient draught A cold flue usually fails to create sufficient draught. Follow the instructions for starting a fire in the ‘Use’ section; open a window. Wood too damp Use wood with no more than 20% moisture. Logs too large Use small pieces of kindling.
Index top A Adding wood smoking appliance 14 Controlling air supply 19 Creosote 19 D 39 Adverse weather conditions, do not burn wood 19 Damage 13 Aerating the fire 19 Damp wood 16 Air combustion control 18 Dimensions 25 Air control 18 Air inlets 17 Air leak 21 Door adjust closing Locking cam 21 21 ash 19 packing plate 21 Ash pan open 19 Ashes remove 19 B Bearing capacity of floor 11 Burning adding fuel appliance is hard to adjust fire is too intense insufficient heat topp
Fireproof inner plates warning 16 fitting 14 Fitting heat shield 14 Floor smooth 16 Floors bearing capacity fire safety 11 11 Inner plates, fire-resistant remove 13 Installing dimensions 25 K Kindling 39 L Flue connecting to connection diameter height maintenance requirements 16 24 11 20 11 Flue cap 11 Lighting fire 17 Lubricant 21 Lubricate 21 M Flue gasses mass flow 24 Maintenance Clean appliance cleaning the glass emai Fire-resistant inner plates flue lubrication sealing Fog,
R Removable parts 13 Remove fire-resistant inner plates 13 Removing ash 19 Replacing glass 21 S Screens deposit 39 Sealing rope for door 21 Secondary air inlet 17 Smoke emissions into the room 10 Smoking appliance 39 Smooth floor 16 Softwood 16 Solving problems glass broken or cracked hot surface placing a load on door requirements stove glass cleaner terms and conditions for insurance ventilation 10, 20-21 10 10 10 20 10 10-11 Weight 24 Wood damp drying right sort storing will no
E&OE