Operating Instructions and Installation Instructions
Appendix 1: Technical data
Model
350CB and
350CB3
360CB and
360CB3
350CB3/WB
Nominal output 6 kW 8 kW 6 kW
Flue connection (diameter) 125 mm 125 mm 125 mm
Flue connection Germany (diameter) 130 mm 130 mm 110 mm
Weight +/- 95 kg +/- 130 kg +/- 130 kg
Recommended fuel Wood Wood Wood
Fuel property, max. length 30 cm 40 cm 30 cm
Mass flow of flue gases 6.6 g/s 8.2 g/s 6.6 g/s
Temperature increase measured in measuring
section
298 K 297 K 298 K
Temperature measured downstream from the flue
spigot
442 438 442
Minimum draught 12 Pa 10 Pa 12 Pa
CO emission (13%O
2
) 0,10 % 0,10 % 0,10 %
NOx emission (13%O
2
) 125 mg/Nm³ 90 mg/Nm³ 125 mg/Nm³
CnHm emission (13%O
2
) 82 mg/Nm³ 113 mg/Nm³ 82 g/Nm³
Particulate emission 10 mg/Nm³ 39 mg/Nm³ 10 mg/Nm³
Particulate emission in accordance with NS3058-
NS3059
3.58 gr/kg 7.86 gr/kg 3.58 gr/kg
Efficiency 77 % 75 % 77 %
Subject to change because of technical improvements