Appendix 1: Technical Data
Series 2180CB
Nominal output 15 kW
Chimney connection (diameter) 200 mm
Weight +/- 190 kg
Weight model 2180CBGD 230 kg
Recommended fuel Wood
Fuel property, max. length 50 cm
Mass flow of flue gases 13.6 g/s
Temperature increase measured in measuring section 268 K
Temperature measured at the appliance outlet 326 °C
Minimum draught 12 Pa
CO emission (13%O
2
) 0,10 %
NOx emission (13% O
2
) 97 mg/Nm³
CnHm emission (13%O
2
) 96 mg/Nm³
Particulate emission 22 mg/Nm³
Efficiency 76 %
22