Appendix 1: Technical Data
Model Series 2170CB and 2570CB
Rated output 10 kW
Chimney connection (diameter) 150 mm
Weight +/- 160 kg
Recommended fuel Wood
Fuel property, max. length 50 cm
Flue gas flow rate 10.1 g/s
Temperature rise measured in the measuring section 260 K
Temperature measured at the appliance outlet 345 °C
Minimum draught 12 Pa
CO emission (13%O
2
) 0,06 %
NOx emission (13% O
2
) 118 mg/N
CnHm emission (13%O
2
) 70 mg/N
Particulate emission 19 mg/N
Particulate emission to NS3058-NS3059 7.1 g/kg
Efficiency 75,9 %