WIRING INFORMATION
Preset 10 Architectural Two is designed to use daisy-chain wiring topology. Unlike its predecessor the Preset 10
Architectural, the Preset 10 Architectural Two has an input (TB2) and output (TB1) connector. Also note that a system
may contain multiple power supplies when voltage drop becomes a concern. Please give us a call if you have any
questions.
POWER SUPPLY
The voltage provided to the Preset 10 Architectural Two must be between 9-15 volts AC or DC. The Preset 10 Architectural
Two has been designed to operate on a standard class 2 “doorbell” transformer. For example Ace Hardware’s model#
ACE36483 10 volt 5 watt transformer.
Single Master Installation
Note: All jumpers installed
CABLE COLOR FROM TO USE
1
120 Ohm Data Cable
Belden 9829 or
Equivalent
Shield
5 Pin XLR Plate
Pin 1
PRE10-A2 Master
TB2-1 Common
White/Blue Stripe Pin 2 TB2-2 Data -
Blue/White Stripe Pin 3 TB2-3 Data +
2
(2) #16 AWG
Stranded Wires
Black
Power Supply
Common TB1-4 Supply
Red Power TB1-5 Supply “hot”
3
120 Ohm Data Cable
Belden 9829 or
Equivalent
Shield
PRE10-A2 Master
TB1-1
Dimmer Cabinet
?
Common
White/Blue TB1-2
?
Data -
Blue/White Stripe TB1-3
?
Data +
Multi Master Installation
Note: Remove JP5
CABLE COLOR FROM TO USE
1
120 Ohm Data Cable
Belden 9829 or
Equivalent
Shield
5 Pin XLR Plate
Pin 1
PRE10-A2 Master
Room 1
TB2-1 Common
White/Blue Stripe Pin 2 TB2-2 Data -
Blue/White Stripe Pin 3 TB2-3 Data +
2
(2) #16 AWG
Stranded Wires
Black
Power Supply
Common TB1-4 Supply
Red Power TB1-5 Supply “hot”
3
120 Ohm Data Cable
Belden 9829 or
Equivalent
Shield
PRE10-A2 Master
Room 1
TB1-1
PRE10-A2 Master
Room 2
TB2-1 Common
White/Blue Stripe TB1-2 TB2-2 Data -
Blue/White Stripe TB1-3 TB2-3 Data +
4
(2) #16 AWG
Stranded Wires
Black TB1-4 TB1-4 Supply
Red TB1-5 TB1-5 Supply “hot”
5
120 Ohm Data Cable
Belden 9829 or
Equivalent
Shield
PRE10-A2 Master
Room 2
TB1-1
Dimmer Cabinet
?
Common
White/Blue TB1-2
?
Data -
Blue/White Stripe TB1-3
?