SPECIFICATIONS
Connector: Phoenix Contact MSTB series 3 position two part terminal block
Model: MSTB MSTB 2,5/3-ST-5,08 Order Number: 17 57 02 2
Phoenix Contact MSTB series 5 position two part terminal block
Model: MSTB 2,5/5-ST-5,08 Order Number: 17 57 04 8
Connector pin out: 1 (C) DMX512 common
2 ( -) DMX512 data - (input)
3 (+) DMX512 data + (input)
1 (C) DMX512 common
2 ( -) DMX512 data - (output)
3 (+) DMX512 data + (output)
4 (C) Supply common (internally tied to pin1)
5 (V) Supply voltage “hot”
Input/Output Circuit: ESD protected EIA-485 transceiver (LT1785)
Indicators: Ten green preset indicator LEDs
One yellow “Grand Master 100%” indicator LED
One yellow “Grand Master 0%” indicator LED
One yellow Fade Time LED
One red Signal / Record LED
User controls: Ten preset push buttons
One “Grand Master Up” push button
One “Grand Master Down” push button
One recessed record push button
One recessed fade time push button
Option Jumpers: For a single station installation all jumpers should be installed.
INSTALLED REMOVED
JP1 Recording Enabled Recording Disabled
JP2 Master Station Slave Station
JP3 Fade to last active preset Hold Last Look
JP4 Single Station Mode Station Mode Multi Station Mode
JP5 Switch Over Mode Highest Takes Precedence (HTP) Mode
JP6 Radio Button Mode Push On Push Off Mode
Power input: 9-15 volts AC or DC, 200mA per station
(A 10 volt class 2 “doorbell” transformer is recommended for fixed installations)
Color: Black anodized with laser engraved nomenclature
Size : Faceplate: 4.5"h X 4.6"w X 0.2"d
Faceplate rear inset: 4.15"h X 4.25"w X 0.1"d