Installation Manual

9
3. Cable Connections:
Make sure that there is sufficient cable length to create all required connections prior to
connecting cables. Add service loop (extra length) in cable runs to allow for position adjustment,
change of mounting location, drip loops, and errors. In some instances, it may be advantageous to
run cables prior to making cable connections. In this case, the following steps must be completed at
the mounting site or short sections of required cables (i.e. “pig tails”) should be left exiting the unit
and connected to the longer cable runs once the unit is installed. All cable junctions must be sealed.
3.1. BASH Original
One Cable Connection:
BASH Original is equipped with a cable gland that contains one hole to accommodate one cable
entering the enclosure. This situation is ideal for PoE cameras and other devices that can be
powered and transmit data with only one cable connection, such as USB or wireless cameras.
Multiple Cable Connections:
If more than one port is required, an alternative multi-port cable gland must be used to ensure
a reliable seal is made around each of the cables. Dotworkz Systems has two port (PN 430-010)
and three port (PN 430-009) options available for these applications. If you have multiple cables
entering the enclosure, contact a Dotworkz representative regarding the appropriate Cable
Gland for you application.
3.1.1. Completely unscrew the outer sealing nut of the cable gland and remove the internal
rubber gland.