Function Directions
ALTI This feature provides an altitude correction to the CO
2
level for increased accura-
cy. Select this feature, then use UP and DOWN to input the current altitude (look it
up if unknown) in meters. Press ENTER once altitude is correct.
ºC/ºF Use this feature to toggle between Celsius and Fahrenheit for the temperature
display. First use UP and DOWN, then ENTER when the desired one is selected.
ADV This function toggles between 4 things when selected: changing the alarm and
lights to suit levels For Low border, or For Hi border, or change the dataloginterval,
or Restore factory setting. Restore factory setting will reset the device to factory
settings and erase all stored data in the chart. To use any of these modes, hold
ENTER for 3 seconds until an audible beep.
Default settings of the trac light:
green LED: below 800 ppm, yellow LED: from 800 ppm and red LED: from 1200 ppm
(Return) Exits the main menu. No options will be displayed on the green bar. A dierent
audible beep be heard in this option.
6.Specications
Typical test conditions, unless otherwise specied: Ambient Temp =23+/-3°C, RH=50%-70%,
Altitude=0~100 meter
Measurement Spec
Operating Temperature: 32°F bis 122°F (0°C bis 50°C)
Storage Temperature: -4°F bis 140°F (-20°C bis 60°C)
Operating & Storage RH: 0-95%, non-condensing
CO
2
Measurement
Measurement Range: 0-5000ppm
Display Resolution: 1ppm (0-1000); 5ppm (1000-2000); 10ppm (>2000)
Response Time / Warm-up Time: <30 sec
Temp. Measurement
Operating Temperature: 32°F bis 122°F (0°C bis -50°C)
Display Resolution: 0.1°F (0.1°C)
Response Time: <20min (63%)
RH Measurement
Range: 5-95%
Resolution: 1%
Power Requirements: 160mA Peak, 15mA average bei 5.0V
Input: 115VAC 60Hz, or 230VAC 50Hz, 0.2A
Output: 5VDC 5.0W max.
Average active eciency: 73.77%
Noload power consumption: 0.075W
Dimension: 4.7x2.6x1.3inch (120x66x33mm)
Weight: 103g only instrument without power supply
7. Rear View:
8. Disclaimers:
USB connection is for power supply only; no communication with PC. Unplugging the device may
result in loss of most recent logged data on the chart.
This device is not intended for workplace hazard CO
2
monitoring, nor intended as a denitive monitor
for human or animal health institutions, life sustenance, or any medical-related situation.
We and the manufacturer assumes no responsibility for any damage or loss suered by the user or
any third party arising through the use of this product or its malfunction.
We reserve the right to change the spec without notice.
9. Explanation of symbols
This sign certies that the product meets the requirements of the EEC directive and has been
tested according to the specied test methods.
10. Waste disposal
This product and its packaging have been manufactured using high-grade materials and components which can be
recycled and reused. This reduces waste and protects the environment. Dispose of the packaging in an environ-
mentally friendly manner using the collection systems that have been set up.
Disposal of the electrical device:
Remove non-permanently installed batteries and rechargeable batteries from the device and dispose of
them separately.
This product is labelled in accordance with the EU Waste Electrical and Electronic Equipment Directive
(WEEE). This product must not be disposed of in ordinary household waste. As a consumer, you are
required to take end-of-life devices to a designated collection point for the disposal of electrical and electronic
equipment, in order to ensure environmentally-compatible disposal. The return service is free of charge. Observe
the current regulations in place!