Installation Guide

16 ICU300 / ICU300T 05-2022DL3107-020
ICU300 / ICU300T Manual Sliding Doors
Track Installation Instructions
14
Positive Latch Adjustment
1
1. Remove astragral on side of door.
2. Adjust pin to provide 1/8” (3.2mm) of Latch Pin Engagement.
3. Test door for proper Latch operation and Breakout function.
1/8”
If Pin Needs To Be
Adjusted Lower.
Remove The Nut
And Add Loctite
.