Installation Technical Manual
36 04045524 - 08/2016 Kaba access manager 92 32
By setting the jumper with the designation CD, the OUT1 output can be used simi-
larly to the outputs OUT2 and OUT3 as potential-free switching contact.
Principle of output wiring Jumper position
IMPORTANT: Only the CD
jumper may be set. All other
jumpers may not be set.
5.7.6.2 Switching 12 V DC to OUT1
By setting the jumper with designation 12 V DC, the internal 12 V DC power supply is
switched to the OUT1 output. Consumers, for example door openers which are oper-
ated with 12 V DC can be directly connected to OUT1 in this way.
This variant can be used both with device power supply via PoE and device power
supply via an external 24 V DC power supply unit.
Principle of output wiring Jumper position
IMPORTANT: Only the jumper
pair 12 V DC may be set. All
other jumpers may not be set.