User`s manual
67
♦ Wait for about 40 seconds the “No Disk” message on your LCD will either disappear (Disk
already initialized on a V1), or a new message saying “No MD Present” will appear. In case
you get “No MD Present”, select the proper compression ratio and initialize the drive. There is
no need to perform a Format command on new drives.
14.4 Mounting Data-Express on the V1x2 without drive sharing
The only available Data Express model for this unit is the DE300i-SWC160/B. Since the V1x2 has 2
internal SCSI cables, one should be connected to the top slot of the DE300i-SWC160/B, the other SCSI
cable should be connected to the bottom slot.
14.5 Mounting Data-Express on the V1x2 sharing a drive
The only available Data Express model for this unit is the DE300i-SWC160/B. To share a disk, there
should be only one internal SCSI cable going from Channel-1 to all 3 connectors of the DE300i-
SWC160/B then to Channel-2.
14.6 Mounting Data-Express on the V1-U
The only available Data Express model for this unit is the DE300i-SWC160/B. Since the V1-U has 1
internal SCSI cable, it should go from the V1-U main-board to all 3 slots then to a LVD terminator.
14.7 Mounting Data-Express on the V1-MP2
The recommended Data Express model for this unit is the DE100i-RSWC160/B.
The following diagram shows how you should setup the receiver