Model 8000XL OPERATOR MANUAL DORAN SCALES, INC. 1315 PARAMOUNT PKWY. BATAVIA, IL 60510 1-800-262-6844 FAX: (630) 879-0073 http://www.doranscales.com MANUAL REVISION: 1.
INTRODUCTION Introducing the Doran Scales Excel Series, Model 8000XL Digital Scale Indicator. This scale uses state of the art technology to provide you with a low cost solution to the most demanding weighing applications. With ease of use and setup in mind, the scale is simple to set up and ready to use. The Model 8000XL offers many features. A few of these features are listed below: ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? NTEP certification for Class III installations to 10,000d.
Unpacking Your Scale Before unpacking your Doran scale, please read the instructions in this section. Your new scale is a durable industrial product, but it is also a sensitive weighing instrument. Normal care should be taken when handling and using this product. Improper handling or abuse can damage the scale and result in costly repairs that may not be covered by the warranty. If you notice any shipping damage, notify the shipper immediately.
Quick Start User's Guide Figure 1. 8000XL Front Panel Layout Basic Weighing Operations: 1) Remove all items from the scale platter. 2) Press ZERO to zero the scale. The weight display should now read zero. 3) Place an item on scale platter and wait for the motion (MOT) indicator to turn off, indicating a stable weight. Power Up: Press and release ZERO to turn on the scale. Turn Off : 1) To turn off manually, press and hold the ZERO pushbutton for 2 seconds or until the display shows "rel Pb.
Indicators: The Doran 8000XL has a main display and eleven indicator lights. These indicators provide the operator with information about the scale and the current weighing operation. The main display is used to provide the operator with the current weight. The units indicators, located on the right of the main display, show the current measurement units. ? The Motion (MOT) located on the left side of the display, informs the operator when the scale is in Motion.
Accumulator and Counter (Hidden pushbutton): Press the Capacity Label / Hidden pushbutton to enter the accumulator / count recall mode. The display will show "Accunn" followed by the accumulated weight, then "Countr" follow by the counter value. The display will continue to repeat this message until a key is pressed. The accumulator / counter recall mode will display the accumulator value in the units currently selected in the weigh mode.
Battery Operation: The 8000XL with battery option is internally equipped with a self-contained rechargeable, sealed, gelled-electrolyte battery and charging circuit. The indicator is designed to run continuously for 60 hours on a fully charged battery with one 350 ohm load cell. The built-in charging circuit will fully charge the battery in approximately four hours. To charge the battery, simply plug the line cord into a standard 115V (230V optional) wall outlet.
Troubleshooting Scale Messages: Message "rEL Pb" Release push button. "Ldg 0" Loading zero. "CLr Ac" Clear accum/counter Meaning The scale has detected that a key has been depressed for more than 3 seconds. The scale is attempting to zero the scale upon startup. This message will remain until scale is stable. The Accumulator and Counter values are cleared out of nonvolatile memory.
Scale reading is bouncing or "flighty". Check for air currents and/or vibration around the scale. If that is the cause it may be necessary to set the Digital Averaging to a higher setting to stabilize the reading. If you are still experiencing a problem with your scale, or if the problem you are having is not covered in the above list, please contact your Doran Scales authorized dealer.