SPECIFICATIONS
Vehicle Systems Testing And Adjusting
Shunt Field Tests
Open Circuit Test
Shunt Coil Open Circuit Test
1. Put the Function/range Switch of the digital multi-
meter on the 200 ohm resistance (A) scale.
2. Put the test leads between the shunt terminals.
3. The resistance must be approximately 5 to 10
ohms. If the resistance is more than this, it is an
indication of corrosion on the terminals or an open
shunt coil.
Ground Test
Shunt Coil Ground Test
1. Put the Function/Range Switch Switch of the
digital multimeter on the 20M resistance (A) scale.
2. Put one test lead to either shunt coil terminal. Put
the other test lead to the motor housing. There
must be more than one megohm resistance.
Check both shunt coil terminals.
3. If the indication is less than one megohm, the
shunt coil is grounded and must be replaced.
Brush Holder Test
Brush Holder Test
(1) Brush holder. (2) End bell.
1. The brush holders are mounted on an insulator at
the commutator end of the motor. Make a visual
inspection of the brush holders and insulator.
2. Put digital multimeter. Function/Range Switch on
the 200 ohm resistance (½) scale. Put one test
lead to brush holder (1) and the other test lead to
the end bell (2). The meter must show overload
(OL).
3. Check each brush holder. If meter reading is low,
the brush holder is grounded. Replace the
insulator.
Tools Needed
Digital Multimeter Or Equivalent 1
Tools Needed
Digital Multimeter Or Equivalent 1