Service manual

G420F(FE) Service Manual 319 Appendix
How to Set New Speed Limit
Maximum RPM for both the NEUTRAL state
(Normal) and IN-GEAR state (Speed Limiting) are
configurable using the MotoView Service Tool.
[Figure 2] Ground Speed Select Screen of the MotoView Service Tool
[Figure 2] shows the Speed Limit screen of the
MotoView service tool. The green boxes are
configurable for both the NEUTRAL MAX RPM
Setpoint and the IN-GEAR MAX RPM Setpoint. The
pressure switch state is displayed at the bottom of
the screen and labeled NEUTRAL SWITCH STATE.
For example, as Figure 2 depicts:
With pushing of inching pedal, the maximum RPM
for normal speed governing (Neutral State) is set at
2600.
With release of inching pedal, the maximum RPM
for limited speed governing (In-Gear State) is set at
2000.
Allowable Range of RPM Limits
Software limits of both Neutral and In-Gear are
displayed on the right side of the Speed Limit screen.
Values that are entered in the configurable “green
boxes” cannot exceed the upper limit value or fall
below the lower limit value.