Service manual

G420F(FE) Service Manual Chapter 9. Advanced Diagnostics 279
Table 1. Fault List Definitions
FAULT DESCRIPTION
CODE
(MI04 CODE)
APP1AdaptHiMax
Learned full pedal end of APP1 sensor range higher than
expected
641
(64)
APP1AdaptHiMin Learned full pedal end of APP1 sensor range lowe 651
APP1AdaptLoMax than expected 661
APP1AdaptLoMin
Learned idle end of APP1 sensor range higher than
expected
631
(63)
APP1RangeHigh
Learned idle end of APP1 sensor range lower than
expected
621
(62)
APP1RangeLow
APP1 sensor voltage out of range high, normally set if the
APP1 signal has shorted to power or the ground for the
sensor has opened
611
(61)
APP2AdaptHiMax
APP1 sensor voltage out of range low, normally set if the
APP1 signal has shorted to ground, circuit has opened or
sensor has failed
642
(68)