Specifications

SW 1 DIP-Switches (Right Hand Side)
SW 2 DIP-Switches (Left Hand Side)
NC
NO
P7
20 19 18 17 16 15 14 13 12 11 10 9 876 54321
Red Full Open
Green Close
White Com
Key Switch
Stand-Alone
Keypad
Stand-Alone
Card Reader
Telephone Entry
3-Button Control Station
DoorKing ONLY
Functions ONLY during gate closing cycle.
Note: All stand-alone and
telephone entry devices must
use a separate power source.
Important: Controls must be
far enough from the gate so
that the user is prevented
from coming in contact with
the gate while operating the
controls. Outdoor or easily
accessible controls should
have a security feature to
prevent unauthorized use.
“Optional” REVERSE GATE
for Closing Direction
Photo Sensors
#1-Com
#1-Com
#5 - Partial Open (See manual)
#4 - Full Open
Com
To #4 or #5
#2 or #5-Relay
250 mamp. max.
#3-24 volt
#1-Relay Com
#2 or #5-Relay
#1-24 Volt Power Com
#3-24 Volt Power
4-Wire Radio Receiver
#2-Fully opens gate.
3-Wire Radio Receiver
Safety Opening Device
SW 1, switch 7: After photo sensor beam
gets obstructed:
OFF Setting - REVERSES GATE.
ON Setting - Stops gate then continues
closing when gate is clear (Same function
as UL 325 terminal #2).
Note: The ON setting is used to help
prevent tailgating but the photo sensor
should be wired to the UL 325 terminal #2
when the “stop gate” function is desired,
see manual for more information.
#5 Terminal Note: Any opening
device connected to terminal #5 will
open the gate to the partial open
setting. Secondary entrapment
protection devices will also open the
gate to the partial open setting. If the
Inherent Reverse Sensor gets
activated during the close cycle, it
will always fully open the gate.
1
ON
2 3 4 5 6 7 8
SW 1 is Upside-Down on Board
1
ON
2 3 4 5 6 7 8
SW 1 is Upside-Down on Board
Auxiliary Common
Terminal
Connect any common
wire to these 2 terminals.
SW 1, Switch 3 MUST be ON
except for dual operators or
exit loop partial open
applications.
Main Terminal
1
ON
2 3 4 5 6 7 8
1
ON
2 3 4
SW 1
Upside-Down on Circuit Board.
SW 2
Upside-Down on Circuit Board.
Note: After a DIP-switch setting is changed, power must be turned
OFF and then turned back on for the new setting to take affect.
Switch Function Setting Description
2
Spare
4
1
Self-Test
Gate Opens
Uphill
3
Gate Opens
Downhill
OFF
ON
Normal Setting. Normal gate operation.
Self-test mode. Operator MUST be disconnected from gate to run self-test.
OFF
ON
Normal Setting. Level gate operation or gate opens DOWNHILL.
MUST be ON if gate opens UPHILL.
OFF
ON
Normal Setting. Level gate operation or gate opens UPHILL.
MUST be ON if gate opens DOWNHILL.
OFF
Leave in the OFF position.
Warn Before
Operate
Reverses Gate
Stops Gate
Switch Function Setting Description
OFF
ON
4-OFF
4-OFF
4-ON
4-ON
5-OFF
5-ON
5-OFF
5-ON
Auto-Close
Timer
Relay Activation
and
LED Indicator
Light Activation
2
1
3
4 and 5
7
8
OFF
ON
OFF
ON
Normal Setting. No sound.
Internal alarm will sound before gate starts and throughout gate’s cycle.
Auto-close timer is OFF. Manual input required to close gate.
Auto-close timer is ON. Adjustable from 1-23 seconds to close gate.
6
Relay activates and LED is ON when the gate is fully open.
Relay activates and LED is ON when the gate is not closed.
Relay activates and LED is ON when the gate is opening and open.
Relay activates and LED is ON when the gate is opening and closing.
Changes the direction the operator
will open/close the gate.
Opening direction
using ON setting.
Opening direction
using OFF setting.
Normal Setting. Input to terminal #6 and/or reverse loops will REVERSE gate
during CLOSE cycle.
Input to terminal #6 and/or reverse loops will STOP gate during CLOSE cycle.
OFF
ON
Exit Loop Port
Output
Full Open Input
The output wired to terminal #4 becomes the output from the exit loop detector
plugged into the EXIT Loop port. Used for dual operator application.
Normal Setting. Terminal #4 is a normal full open input.
OFF
ON
Normal Setting. Timer will function normally.
Opening gate will stop and begin to close as soon as all reversing inputs (Reverse
loops, photo sensors) are cleared regardless of the distance the gate has opened.
Quick-Close
Timer Override
QUICKSTART “BASIC” GUIDELINES FOR MODEL 9500 - DIP-SWITCH AND WIRING REFERENCE
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Model 9500 is intended for installation only on sliding gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the Installation/Owner’s manual.