Specifications
24” depth up to 8,000 lb. gate.
36” depth up to 25,000 lb. gate.
Above Ground
Top MUST
Be Level!
Use twelve (12)
1/2” x 3” sleeve
anchors (not
supplied) to
secure operator
to concrete pad.
Chain
Bracket
Chain
Bracket
Chain
Bracket
Chain
Bracket
4” minimum from operator chassis to gate.
15”15”
Operator MUST be PARALLEL to gate!
Chain brackets MUST align
with idler wheels so chain
stays PARALLEL to gate!
Chain brackets MUST be
mounted so the chain
remains the same height
as it is on the idler wheels!
10.5”10.5”
4” Min.
12”
12”12”
12”12”
12”
Wire Mesh
Re-bar
Re-bar
Sleeve
Anchors
Idler Wheels
15”15”
4”
4”
Re-bar
56”
36”
Concrete Pad
Concrete Pad
3/4” Conduit
3/4”
Conduit
(Sweeps)
Chain
Tray
Mechanical
Disc Brake
11”
1/2
Anti-Grounding Plate
TIME
DELAY
EXIT
LOOP
LMT
REVERSE
LOOP
REV SENSE
OPEN
REV SENSE
CLOSE
1
ON
2 3 41
ON
2 3 4 5 6 7 8
NC
NO
P8
P7P6
4404-010
20 19 18 17 16 15 14 13 12 11 10 987654321
94109410
1
2
5
6
11
13A
13B
13E
25
16
17
U
L1 L2/N B- B+
VWPE PE
Mode
EPM
Speed
Controller
1.0
PE
SCM series
basic I/O control
115 VAC Convenience Outlets
DO NOT power up and
cycle the operator until
the “DIP-Switches” and
the “Limit Switches”
have been adjusted.
Damage could occur to
the gate and operator.
T
T
T
T
T
T
T
T
T
Manual Crank Stored
See reverse side to wire main terminal.
QUICKSTART “BASIC” GUIDELINES FOR MODEL 9500 “FULL OPEN”
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Model 9500 is intended for installation only on sliding gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions,
please refer to the installation/owner’s manual.
Copyright 2013 DoorKing, Inc. All rights reserved.
9500-066-G-3-13
Plug-In Loop Detectors
Not included - Refer to the Installation/Owner’s manual AND
Loop Information Manual (available from www.dkaccess.com)
for more information on loops and plug-in loop detectors.
Important Note: DoorKing highly recommends that loops and
loop detectors are installed with this slide gate operator. A loop
detection system will preventing the gate from automatically
opening or closing on a vehicle when it is in the gate’s path.
High Voltage Connection
Tip: It is recommended that a surge suppressor be installed on the
high voltage power lines.
GATE OPERATOR MUST BE PROPERLY GROUNDED!!
DIP-Switches
Limit Switches
1. Opening Direction
2. ON
3. ON
4. OFF
5. OFF
6. OFF
7. OFF
8. OFF
1. OFF
2. OFF
3. OFF
4. OFF
Auto-Close Timer
Chassis
Ground
DANGER
HIGH VOLTAGE!
DANGER
HIGH VOLTAGE!
1
ON
2 3 4 5 6 7 8 1
ON
2 3 4
SW 1 and 2 are Upside-Down on Circuit Board.
123
TIME
DELAY
A
B
D
B
D
1 ft/s
.5 ft/s
0 ft/s 2 ft/s
1.5 ft/s
Speed Control
Knob
Limit LEDs
Plug-In Loop
Detector
Plug-In Loop
Detector
MinMax
Speed
Push
Push
Lock-Plate
Limit Nut
Limit Nut
Slow-Down Limit
Slow-Down Limit
1A
2A
Partial Open
Not Used
Chain Tray Note: Recommended
for longer gates to support the
weight of the chain. DoorKing
offers a chain tray and supporting
brackets in sections to fit any
length gate. (DoorKing P/N
2601-270 10 Ft. section)
Manual Crank Note:
Model 9555/9556 mechanical disc
brake MUST be disengaged
BEFORE manually operating the
gate (See manual).
Manual Crank:
refer to manual
for manual gate
operation.
1
2
2A
1A
Adjust 1 to 23 sec.
Re-Bar:
4 per 12” x 12”
concrete post.
3/4”
Conduit
1 Limit
Switch
2 Limit
Switch
Partial Open Adjustment Rail
CAUTION
High Voltage AC input power MUST MATCH
the operator specifications or DAMAGE will
occur and VOID the warranty!
See reverse side
With power OFF, push and hold the
lock plate down where shown to
adjust the Open and Close limit
nuts.
After adjusting the limit-nuts, be
sure that the lock-plate is engaged
in the slots on the limit-nuts to
prevent them from rotating.
The slow-down limits will move up
or down 3/4 inch. DO NOT remove
the slow-down limit assembly from
the 3/4 inch slot and re-attach it in
the longer slot on the partial open
adjustment rail to gain further
adjustment. This will cause
mechanical damage to the switch
assembly when the operator is
activated.
Turn power ON and activate the gate
operator.
Re-adjust the limit nuts as neces-
sary for full-open and full-close gate
travel. After you are satisfied with
the gate limit settings, the speed
control knob can then be adjusted
to personal preference.
EXIT
LOOP
LMT
REVERSE
LOOP
REV SENSE
CLOSE
P8
P7
P6
4404-010
Electronic Box
1
2
5
6
11
13A
13B
13E
25
16
17
L1 L2 L3
B- B+
Mode
EP
M
0 0 0
SCM series
basic I/O control
1 ft/s
.5 ft/s
0 ft/s 2 ft/s
1
.5 ft/s
Power safety and opening devices
that require 115 VAC power.
Two 115 VAC Convenience Outlets
208/230/
460 VAC
THREE Phase
Chassis
Ground
High Voltage
AC Input Wire
Hot
115 VAC Output
Hot Hot
208/230 VAC
SINGLE Phase
Chassis
Ground
High Voltage
AC Input Wire
Hot
115 VAC Output
Hot
Use only two legs of the
incoming 3-phase power.
A
A
Check polarity of Three Phase:
Position the gate half way open.
Give open command and while
gate is opening, activate the
appropriate limit switch with
your finger. Gate should STOP.
If it does not, activate the other
limit switch. If this STOPS the
gate, AC power wires must be
changed (Reverse the
connection of any 2 wires and
re-check limits).
VERIFY Input AC power
MATCHES your
specific operator
power BEFORE wiring!