Technical information

TROUBLE SHOOTING - DOORKING SLIDE GATE OPERATORS, MODEL 9100 & 9150
Operator Adjustments
IncreaseDecrease
Adjust
Jamb Nut
Tighten
Clutch
Loosen
Clutch
1) Loosen Center
Hex Lock Screw
Adjust Reverse
Sensitivity
on Control Board
OFF
AC
POWER
RESET
OFF
Battery
POWER
Power Switch for
optional Battery
Back-up
Detect LED
Solid Red - indicates vehicle presence, or that
detector is "Locked ON"
Flashing Red - Indicates that a failure occured in
Loop Circuit. If detector has automatically reset, this
will continue to flash showing that a fault had
occured.
Reset
Button
Sw 2
Sw 3
Sw 4 = Sens
Boost
Sensitivity
Frequency
Switches
Power LED
Detect LED
1
2
Frequency
High 1 OFF, 2 OFF
Med-Hi 1 OFF, 2 ON
Med-Lo 1 ON, 2 OFF
Low 1 ON, 2 ON
1
2
3
4
Operation Settings
Fast Trak 1 OFF=Normal
1 ON = Fast Trak
Sensitivity
Low 2 OFF, 3 OFF
Med-Lo 2 OFF, 3 ON
Med-Hi 2 ON, 3 OFF
High 2 ON, 3 ON
Sensivity 4 OFF= Normal
Boost 4 ON = Boost
Reset Button
Press to reset Detector, or
when changing
Frequencies &/or Sensitivity
Lock
Unlock
ACCESS CONTROL SOLUTIONS . . . 14 Preventative Maintenance Guide
Figure 3