User Manual

5.1.4 Elevator Board / Floor Hardware Test
This testing sequence will allow you to check activation of individual relays on the elevator control
board(s) and will confirm communication between the 1838 circuit board and the elevator control
board(s).
1. Press *
7 7 and enter the four-digit mast er code _ _ _ _ (beep).
2. Enter the elevator shaft number _ (1, 2, 3 or 4) then press *
(beep).
3. Enter the two-digit floor number _ _ , then press *
(beep).
4. The relay LED on the elevator control board that represents the floor number entered will
turn ON for approximately 1 second.
5. To check other floor relays , repeat steps 2 and 3.
6. When complete with the testing, press 0
# TOGETHER to end this testing sequence.
NOTE: This program test sequence will automatically end itself if no keypad inputs are
detected after approximately 30 seconds.
Refer to the Elevator Control board installation manual for more information on trouble
shooting the elevator control boards.
5.1.5 Modem Output Level
This program
ming sequence sets the output level of the modem tones. This programming step
should only be used if you are experiencing modem trouble. A higher setting increases the tone
volume while a lower setting decreases the tone volume.
Factory setting is: 4
1. Press *
9 0 and enter the four-digit mast er code _ _ _ _ (beep).
2. Enter a modem level _ (1 through 8) the n press *
(beep).
3. Press 0
# TOGETHER to exit this programming step.
1838-065
-U-4-13 Page
47