User Manual
3.7 ANTI-PASS BACK
The pro
gramming steps below will allow you to set up and program some basic functions for the anti-
pass back feature. However, you must set up the IN and OUT relay programming table in the
Remote Account Manager softwa re. Re fer to manual 1835-066.
3.7.1 Programming the Anti-Pass Back Mode
Anti-Pass
Back (APB) can be set to operate in one of three different modes. PASSIVE APB records
an APB Violation and will allow entry or exit. ACTIVE APB records an APB Violation and will not
allow entry or exit. TRAP APB records an APB Violation and will allow entry but not exit.
1. Press *
4 3 and enter the four-digit MASTER CO DE _ _ _ _ (beep).
2. Enter 0
for OFF, 1 for PASSIVE, 2 for ACTIVE or 3 for TRAP, then press * (beep).
3. Press 0
# TOGETHER to end this progra mming step.
3.7.2 Re-Sync All Devices
This
programming step is used to allow all cards one ‘move’ either in or out without causing an APB
Violation to be recorded.
1. Press *
4 5 and enter the four digit MASTER CODE _ _ _ _ (beep).
2. Press 1
to Re-Sync ALL devices or press 0 to not Re-Sync, then press * (beeeeeep).
3. The programming sequence will end itself after all cards are re-sy nced.
3.7.3 Re-Sync Individual Devic es
This p
rogramming step is used to re-sync a single card only.
1. Press *
4 6 and enter the four digit MASTER CODE _ _ _ _ (beep).
2. Enter the five digit device number _ _ _ _ _ then press *
(beep).
3. Press 0
# TOGETHER to end this progra mming step.
3.7.4 Reset Facility Counter
This programming step is used to reset the facility counter. The facility counter keeps track of the
number of “IN’s” and “OUT’s” when using APB mode.
1. Press *
4 8 and enter the four digit MASTER CODE _ _ _ _ (beep).
2. Enter a five digit number that you want the count to start at _ _ _ _ _ then press *
(beep).
(Example: to start at 25, enter 00025)
3. Press 0
# TOGETHER to end this progra mming step.
1838-065
-U-4-13 Page
37