User Manual

3.6 FOUR-DIGIT ENTRY CODE
A Do
orKing remote keypad (P/N 1814-075) is required if four-digit entry codes are going to be used to
access a door or gate. It is important to understand that four-digit entry codes are not the same as a
five-digit PIN (Personal Identification Number) code inputted to the system from a wiegand keypad.
Four-digit entry codes can only activate relays 0, 1 or 2 on the 1838 circuit board, regardless if
Tracker expansion boards are used or not. If Tracker expansion boards are controlled by relay 2, the
four-digit entry codes must be set to activate relay 0 or 1. If relays 1 and 2 are used to control
Tracker expansion boards, then four-digit entry codes must be set to activate relay 0.
3.6.1 Programming Four-digit Entry Codes
1. Press *
0 2 and enter the four-digit MASTER CODE _ _ _ _ (beep).
2. Enter the directory code (1, 2, 3 or 4 digits depending on what was programmed in
3.4.1) then press *
(beep).
3. Enter the four-digit entry code _ _ _ _ then press *
(beep).
4. Repeat steps 2 and 3 to enter additional entry codes.
5. Press 0
# TOGETHER to end this programming ste p (beeeeeep).
3.6.2 Delete Four-digit Entry Codes
1. Press *
0 2 and enter the four-digit MASTER CODE _ _ _ _ (beep).
2. Enter the directory code (1, 2, 3 or 4 digits depending on what was programmed in
3.4.1) then press *
(beep).
3. Press #
# # # * (beep).
4. Repeat steps 2 and 3 to delete more entry codes.
5. Press 0
# TOGETHER to end this programming ste p (beeeeeep).
3.6.3 Entry Code Ranges
Four-di
git entry codes can be made to activate relay 0, relay 1, relay 2 or any combination of relays
by programming HI and LOW ranges for each relay. Ranges may overlap, which will cause more
than one relay to activate if this is desired. For example, if the low boundary for relay 1 and 2 is 2000,
and the hi boundary is 3000 for relay 1 and 4000 for relay 2, then entry codes between 2000 and
3000 will activate both relays, and entry codes between 3001 and 4000 will only activate relay 2.
1. Press *
1 2 and enter the four-digit MASTER CODE _ _ _ _ (beep).
2. Press 0
* to set relay 0, 1 * to set relay 1, or 2 * to set relay 2 boundaries.
3. Enter the four-digit low boundary _ _ _ _ then press *
(beep).
4. Enter the four-digit high boundary _ _ _ _ then press *
(beep).
5. Repeat steps 2, 3, and 4 to set the other relay boundaries (or p ro cee d to step 7).
6. Press 0
# TOGETHER to end this programming ste p (beeeeeep).
Page 36 1838-065-U-4-13