Operator SWING-3000/5000 Installation and Operating Manual © DoorHan, 2014 contents 2 General Information 2 Safety instructions 3 Operator unit 5 Operator Installation 5 Extreme Positions Adjustment 9 Release Operation 10 maintenance 10 Troubleshooting 10
Contents CONTENTS 1. General Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.1. Range of use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.2. Technical specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety instructions 1.2. Technical specifications Operator Swing-3000 Swing-5000 Weight, kg 10 11 Supply voltage, V/Hz 220–240/50 Rated power, W 150 Intensity, % 50 Protection rating IP54 Gear ratio 1/36 Rod speed, mm/s 15 Force, N 3 000 Working temperature range, °C –40…+55 Capacitor, mf 10 1.3. Operator package Upon receiving the operator, unpack it and inspect it carefully. If any signs of damage are observed, please contact your supplier.
Safety instructions Mechanical units of the gate shall conform to the standards EN12604 and EN 12605. Prior to installation, check that the location of operator installation is suitable by its climatic conditions to technical specifications of the operator. Do not install the operator in premises containing quick inflammable substances or other dangerous environments as it can cause explosion or fire.
Operator unit 3. Operator unit Nut M8 Гайка М8 5 6 1. 2. 3. 4. 5. 6. 2 1 4 M8×10 Operator Front bracket Rear fork Rear bracket Release unit Lead screw M8×50 3 Swing-3000 88 126 793 300 Stroke Swing-5000 88 126 993 500 Stroke 4. operator installation 4.1. Tools 1 2 1. 2. 3. 4. 5 Set of spanners Set of slotted and cross screwdrivers Set of drills for metal Set of drills for concrete 6 3 5. 6. 7. 8.
operator installation 4.2. iNSTALLation layout Warning! RISK OF INJURY! Have a qualified technician lay the cables 220-240 V AC. The cables must be laid in protective corrugated tubes. Avoid contact of cables and moving parts of the door. In case of supply cable damage, use the suitable type of the cable. Cables needed for installation of the Swing-3000/5000 operator and accessories (if available): cable 2 × 0.5 mm2 (photocell transmitter, stepped control button); cable 2 × 1.
operator installation 4.3. Inward gate opening Warning! Make sure, that the dimension C does not exceed the value indicated in the table below. Otherwise it is necessary to improve the pole according to the indicated dimension value.
Electrical Connections 4.4. Outward gate opening (SWING-5000) 1) Position the rear bracket in accordance with the dimensions A and B, listed in the table. 2) Install and fasten the rear bracket to the pole using an additional bracket. 3) Open the gate, measure distance D and fasten the front bracket to the gate leaf.
Extreme Positions Adjustment 5. Extreme Positions Adjustment 5.1. Preparation Screw casing Cover 1. Unscrew 2 tapping screws and remove the cover. 2. Unscrew 2 tapping screws and remove the lead screw casing. Nut M8 Lead screw 3. Install the front and back brackets on the operator. 5.2. Open position 1. Release the operator and put the gate leaf in fully open position. 2. Unscrew fastening of the opening limit switch. 3.
Release Operation 6. Release Operation 1. 2. 3. 4. Lift the cover. Insert the key and turn it by 180° Open or close the gate by hand. To link the operator, turn the key by 180° again. Warning! Before releasing (linking) the operator, disconnect power supply. Key 180° Cover 7. Maintenance The Swing-3000/5000 automatic system does not require any special servicing. Repairs may be carried out only by a qualified technician trained and certified at an authorized DoorHan centre.
Notes
Notes 12
Notes 13
We very much appreciate that you have chosen the product manufactured by our company and believe that you will be satisfied with its quality. For information on purchasing, distribution and servicing contact DoorHan central office at: Kralovsky VRCH 2018, Kadan, 43201, Czech Republic Telephone: +420 474 319 111 E-mail: europe@doorhan.com www.doorhan.