11
Note:
After setting or resetting the remote control, press the button within 100 ft. (30 m) from the gate opener to test if
the gate will open/close/stop on your command. If not, check if the control board of the gate opener operates well.
Note:
To disengage the gate opener, move the gate to the middle position, then close the clutch and press the open button of
external button switch to open the gate. If the gate opening direction is wrong, adjust the toggle switch SW1 on the
control board or exchange the two motor lines U and W. Please seriously observe whether the motor can stop
automatically when the gate is fully opened. If the position cannot be adjusted correctly, please exchange limit
switch lines CLLM and OPLM.
The DIP switches on the control board control the external buttons control mode and the auto-close
time settings.
Switch 1: External Buttons Settings
ON = external button only can open the gate
OFF = external button can open/stop/close the gate
Switches 2 & 3:
Auto-Close Time
Settings
DIP Switches
Step 1
Remove the short wire connecting the I.R and GND interface terminals on the control board.
Step 2
Install the photocell infrared sensor on your gate posts according the instructions of your photocell infrared sensor.
Step 3
Connect the sensor to the control board according to the image below.
Photocell Infrared Sensor Installation
Switch Orientations Auto-Close Time
2 ON 3 OFF 15 seconds
2 OFF 3 ON 30 seconds
2 OFF 3 OFF 45 seconds
2 ON 3 ON Auto-Close Disabled