User's Manual

10
11报警次数alarm count该参数表示从主板上电起至当前的总计报警次
数,断电后清零。
11. The alarm count is total alarms quantity that counted from the system power
on of the last time. When the power off, the number is resume to 0.
12峰值门限peak gated, 低位low默认值是 150高位high默认
2047 设置范围是 0-2047峰值门限参数的数值范围是区间表达, 2 个有效
区间range_1 range_2系统采集到的信号特征(峰值)数值,只要在其中任
一区间范围内,则被为是标签信号。峰值位(low)是报警最重要的参数之一,
参数越小,报警的概率越高,反之报警的概率越低。在不误报的情况下,可以通过减
小该参数来提高天线识别标签的距离。
12The peak gated low value is set at 150 and high value is set at 2047 by factory.
The setting range is 0-2047. The range of peak gated is 2 effective intervals (range_1
and range_2). The characteristic (peak) value of the signal collected by the system is
regarded as the label signal as long as it is in any range. The low peak is one of the
most important parameters of alarm. The smaller the parameters, the higher the
probability of alarm, otherwise the lower the probability of alarm. If there is no false
alarm, the detection distance can be wider by reducing this parameter.
13信噪比门限snr gated低位low默认值是 3设置范围是 0-255
高位high默认是 255信噪比门限参数的数值范围是区间表达, 2 个有效区间
range_1 range_2系统采集到的信号特征(信噪比门限)数值,只要在其中
任一区间范围内,则被认为是标签信号。信噪比低位(low是报警最重要的参数之
一,参数越小,报警的概率越高,反之报警的概率越低。在不误报的情况下,可以通
过减小该参数来提高天线识别标签的距离。
13. The signal to noise ratio (snr gated), the low bit (low) default value is 3, the
setting range is 0-255, and the high (high) default is 255. The numerical range of snr
is expressed by interval. The parameters are 2 effective intervals (range_1 and range_2).
The signal characteristics (signal-to-noise ratio threshold) values collected by the
system are considered as label signals as long as they are in any range. Low signal-to-
noise ratio (low) is one of the most important alarm parameters. The smaller the
parameters, the higher the alarm probability, otherwise the lower the alarm probability.
The smaller the parameters, the higher the alarm probability, otherwise the lower the
alarm probability. If there is no false alarm, reduce this parameter, the detection
distance will be wider.
14报警数据alarm data选择报警数据alarm data图框, 点击
按钮可以显示 1 组最新的报警数据日志,报警数据中包括出现报警时的报警次数序