Installation and Operation Manual Installation, Operation, and Bin Vent Models TBV-2, TBV-4, and TBV-6 Service Information This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Illustrations are for reference only as actual product may vary. This manual is property of the owner. Leave with the unit when set-up and startup are complete.
Donaldson Company, Inc. Application of Fume Control Equipment Combustible materials such as buffing lint, paper, wood, metal dusts, weld fume, or flammable coolants or solvents represent potential fire and/or explosion hazards. Use special care when selecting, installing, and operating all dust, fume, or mist collection equipment when such combustible materials may be present in order to protect workers and property from serious injury or damage due to a fire and/or explosion.
Bin Vent, Models TBV-2, TBV-4, and TBV-6 Contents Data Sheet................................................................ 3 Description.............................................................. 4 Purpose and Intended Use........................................ 5 Operation................................................................ 6 Filter Cleaning....................................................... 6 Inspection on Arrival................................................
Donaldson Company, Inc. Description Torit Bin Vents (TBVs) apply cartridge technology to a continuous-duty dust collection system, offering significant advantages. They are designed specifically for silo, storage bin and conveyor transfer applications. Standard models include both the Insertable-mounted cabinet and the Plenummounted cabinet, with each available in three filter configurations: a two (2) filter unit (TBV-2), a four (4) filter unit (TBV-4) and a six (6) filter unit (TBV-6).
Bin Vent, Models TBV-2, TBV-4, and TBV-6 Purpose and Intended Use Misuse or modification of this equipment may result in personal injury. Do not misuse or modify. The Torit Bin Vent is used to vent displaced air and contain valuable and/or harmful products in bins or silos. As materials are conveyed to a bin by various means (mechanical, gravity, and pneumatic), air inside the enclosed bin is displaced. The process by which excess air is removed is called bin venting.
Donaldson Company, Inc. Operation During normal operation, contaminated or dustladen air enters the TBV through the cabinet opening at the bottom of the unit, which is fastened to the silo or storage container. The dust-laden incoming air is collected on the outside surface of the filter elements. As the dust cake collects on the outside filter surface, gravity and air pulse-jet cleaning force the dust to drop back into the storage bin.
Bin Vent, Models TBV-2, TBV-4, and TBV-6 Inspection on Arrival 1. Inspect unit on delivery. 2. Report any damage to the delivery carrier. 3. Request a written inspection report from the Claims Inspector to substantiate claim. 4. File claims with the delivery carrier. 5. Compare unit received with description of product ordered. 6. Report incomplete shipments to the delivery carrier and your Donaldson representative. 7. Remove crates and shipping straps.
Donaldson Company, Inc. Rigging Instructions Failure to lift the collector correctly can result in severe personal injury or property damage. Do not lift unit by the door handle. Electrical installation must be performed by a qualified electrician and comply with all applicable national and local codes. Use appropriate lifting equipment and adopt all safety precautions needed for moving and handling the equipment.
Bin Vent, Models TBV-2, TBV-4, and TBV-6 Standard Equipment Ship Loose Items Items shipped loose with the TBV may include: • Blower/Motor Pack* • • • • • Filter Cartridges* Magnehelic/Photohelic Gauge Solid State Timer Control Box Plenum Silencer Damper Assembly *In general, Torit Bin Vents are shipped without the blower/motor packs installed (shipped loose) to better protect the equipment during transit. Filter cartridges are shipped installed in the TBV plenum models.
Donaldson Company, Inc. venturi Filter Installation for TBV Insertable The filter cartridges in the TBV insertable model extend past the bottom of the cabinet when installed. The filter cartridges would be crushed and damaged under the weight of the collector if they were shipped installed; therefore, they are shipped loose and installed at the customer site once the unit has been installed into a permanent location.
Bin Vent, Models TBV-2, TBV-4, and TBV-6 collar bracket hold down knob filter/venturi assembly roof support slide bar TBV door/hood access notch blow pipe clean air plenum tool-less quick release pipe coupler TBV Filter Installation 11
Donaldson Company, Inc. Solid-State Timer Installation 2. Plug the program lug into the pin that corresponds to the number of solenoid valves controlled. The standard control panel includes a solid-state timer used to control the filter cleaning system. Install the control box and customer-supplied fan starter switch in a convenient location. Install conduit and wire to the unit. 3. With power supply ON, check the operation of the solenoid valves.
Bin Vent, Models TBV-2, TBV-4, and TBV-6 Solenoid Connection The unit is equipped with 115-Volt solenoid valves that control the pulse-cleaning valves, which clean the filters. Wire the solenoids to the solid-state timer following the wiring diagram supplied with the unit. Filter life and cleaning operation will be affected if not wired correctly.
Donaldson Company, Inc. Compressed Air Installation Turn compressed-air supply OFF and bleed lines before performing service or maintenance work. The compressed-air supply must be oil and moisture free. Contamination in the compressed air used to clean filters will result in poor cleaning, cleaning valve failure or poor collector performance. NOTICE Purge compressed-air lines to remove debris before connecting to the unit’s compressedair manifold. 1.
Bin Vent, Models TBV-2, TBV-4, and TBV-6 *low voltage (120 VAC) magnetic starter (blower motor) *power supply disconnect switch solid state control timer box (3-pin timer panel) *electrical motor connection hood access door T-handle quick latch lifting lugs (4) blower/motor (power pack) *solenoid valves electrical connection diaphragm valve air manifold magnehelic gauge solenoid enclosure *automatic condensate valve *air line to manifold *air regulator *air filter (bleed type) *lock-out shut-off va
Donaldson Company, Inc. Magnehelic Gauge The Magnehelic is a differential pressure gauge used to measure the pressure difference between the cleanand dirty-air plenums and provides a visual display of filter change requirements. The high-pressure tap is located in the dirty-air plenum and the lowpressure tap is located in the clean-air plenum. The pressure taps for this gauge are factory installed.
Bin Vent, Models TBV-2, TBV-4, and TBV-6 1/8-in NPT x 90° male elbow clean-air plenum Magnehelic gauge high-pressure port low-pressure port 3/8-in flat washer 1/8-in NPT coupling two, 1/8-in NPT adapters mounting bracket #6-32 x 1/4-in mounting screws plastic tubing two, 1/8-in NPT pipe plugs two, self-drilling screws support structure mounting surface 1/8-in NPT x 90° male elbow dirty-air plenum drill location 3/8-in flat washer 1/8-in NPT adapter 1/8-in NPT x 90° elbow static pressure tee Magnehe
Donaldson Company, Inc. Preliminary Start-Up Check Start-Up 1. Check all electrical connections for tightness and contact. 1. Turn compressed-air supply ON. Adjust regulator to 90-psi. 2. Check for and remove all loose items in or near the inlet and outlet of the unit. 2. Turn blower fan motor ON. 3. Check that all remote controls are wired into the control system and all service switches are in the OFF position. 4. Check that all optional accessories are installed properly and secured. 5.
Bin Vent, Models TBV-2, TBV-4, and TBV-6 down knobs. Reach down inside the venturi and grasp the collar bracket; twist it to the right (clockwise) until the filter hold-down collar clears all four screw studs. Pull up and out to remove the filter element assembly from the unit. 4. Carefully turn the filter element assembly upside down (venturi-side down). Turn the filter crank counterclockwise until completely unscrewed from the quick-nut assembly located in the center of the collar bracket.
Donaldson Company, Inc. Filter Element Installation See the Filter Installation for TBV for first time filter installation for insertable models. NOTICE 1. Place the new filter element end-cap down (gasket-side up). Slide the filter hold-down collar inside the open of the filter element until it stops. 2. Slide the steel grounding tab through the filter crank rod, followed by the rubber-backed washer, rubber side up and away from the crank handle. 3.
Bin Vent, Models TBV-2, TBV-4, and TBV-6 Optional Equipment Photohelic Gauge The Photohelic combines the functions of a differential pressure gauge and a pressure-based switch. The gauge function measures the pressure difference between the clean- and dirty-air plenum and provides a visual display of filter condition. The high-pressure tap is located in the dirty-air plenum and a low-pressure tap is located in the cleanair plenum.
Donaldson Company, Inc. 4. Thirty-five feet of plastic tubing is supplied and must be cut in two sections. Connect one section of tubing from the gauge’s high-pressure port to the pressure fitting located in the dirtyair plenum. Connect remaining tubing from the gauge’s low-pressure port to the fitting in the clean-air plenum. Additional tubing can be ordered from your representative. 5. Zero and maintain the gauge as directed in the manufacturer’s Operating and Maintenance Instructions provided. 6.
Bin Vent, Models TBV-2, TBV-4, and TBV-6 Delta P Control Description The Delta P Control monitors the differential pressure between the clean and dirty air plenums, providing a visual display of the filter condition. When combined with a pulse timer, it controls the pressure drop by turning the cleaning mechanism On and Off at the chosen limits. There are three (3) set points: High Pressure On, Low Pressure Off, and Alarm.
Donaldson Company, Inc. Delta P Plus Control The Delta P Plus Control monitors the differential pressure between the clean and dirty air plenums, providing a visual display of the filter condition. When combined with a pulse timer, it controls the pressure drop by turning the cleaning mechanism on and Off at the chosen limits. There are three (3) set points: High Pressure Drop On, Low pressure drop Off, and Alarm.
Bin Vent, Models TBV-2, TBV-4, and TBV-6 Power Pack Assembly The 1 HP through 5 HP power packs are designed to be side-mounted at the rear of the unit. The fan blower housing is factory mounted to the unit. The blower/motor pack can be installed at any time during installation of the TBV. If the TBV needs to be moved or lifted after the blower/motor pack has been installed, special precautions and careful handling need to be observed to prevent overturning.
Donaldson Company, Inc. 1. Attach the motor to the motor mounting plate with four (4) mounting bolts and washers. Torque down the bolts to the following specifications: Motor Torque (ft./ lbs.) Bolt Size 1 HP 2 HP 3 HP 5 HP 15 15 15 35 3/8-in 3/8-in 3/8-in 1/2-in 2. Loosen the two set screws in the fan wheel and slip on to the motor shaft. The key in the motor shaft should be lined up with the slot in the fan wheel.
Bin Vent, Models TBV-2, TBV-4, and TBV-6 Weather Hood Exhaust Damper The weather hood keeps rain, snow and birds from entering the unit, all of which can cause the TBV to function improperly. It is strongly recommended for units that are not powered or ducted. To install the weather hood, place 1/4-in diameter sealer between the cabinet side and the weatherhood. Position the weather hood over the outlet hole and attach to the cabinet using the eight (8) 5/16-in bolts provided.
Donaldson Company, Inc. Plenum Silencer Plenum silencers are available for the blower/motor assemblies. The plenum silencers are designed to be mounted on the side of the TBV in line with the selected blower/motor assembly. The plenum silencers are equipped with an exhaust damper for flow control, making it unnecessary to select a separate damper assembly for the selected blower/ motor assembly.
Bin Vent, Models TBV-2, TBV-4, and TBV-6 Troubleshooting Problem Probable Cause Remedy Blower fan and motor do not start Improper motor wire size Rewire using the correct wire gauge as specified by national and local codes. Check and correct motor wiring for supply voltage. See motor manufacturer's wiring diagram. Follow wiring diagram and the National Electric Code. Correct wiring for proper supply voltage.
Donaldson Company, Inc. Troubleshooting Problem Probable Cause Remedy Insufficient airflow continued Lack of compressed air Check that a minimum of 90-psig is available. See Compressed Air Supply section. Use a voltmeter to check supply voltage to the timer board. Check and replace the fuse on the timer board if necessary. See Solid-State Timer section. Clean out dust storage area. See Dust Disposal section. Lock out all electrical power to the unit and bleed the compressed air supply.
The Donaldson Torit Warranty Donaldson warrants to the original purchaser that the major structural components of the goods will be free from defects in materials and workmanship for ten (10) years from the date of shipment, if properly installed, maintained and operated under normal conditions.