Specifications
8
Installation, Operation and Maintenance Manual
PowerCore
®
Dust Collectors – Series CPV
INSTALLATION
Where equipment is installed in a Potentially Explosive Atmosphere,
care should be taken not to locate or use the collector where external
ignition sources can be introduced, for example stray electric currents,
lightening, electromagnetic waves, ionising radiation, ultrasonic waves.
General guidance to lifting
Refer also to Figure 2
The collector should be lifted using the lifting eyebolts provided.
During all lifting operations a crane or fork lift with an adequate SWL
(safe working load) must be used. (Refer to lifting label located adjacent
to lifting eyebolts for weight of equipment supplied by Donaldson).
Slings with an adequate SWL (safe working load) must be used. (Refer
to lifting label located adjacent to lifting eyebolts for weight of equipment
supplied by Donaldson).
Use clevis connectors, not hooks, on lifting slings.
Use spreader bar to prevent damage to collector casing.
Take centre of gravity into consideration when lifting collector.
Figure 2 Four-point lifting arrangement (CPV-4 illustrated)
Angle not to exceed
30° from vertical
30
°°
°°
°
Do not lift
with this orientation