Specifications

20
Installation, Operation and Maintenance Manual
PowerCore
®
Dust Collectors – Series CPV
SPECIFICATION
TABLE 3 – COMPRESSED AIR REQUIREMENTS
a
Normal operating pressure.
b
Recommended initial setting; this may be varied with experience.
c
Sizes suitable for runs of pipe up to 30 m (100ft) in length. For longer runs consult with Donaldson.
*Estimated data.
1 bar = 10
5
Pa
CPV-2 6.2 bar 90 psig 10 m³/h* 5.9 cfm* 100 ms ½" NB (12)
CPV-3 6.2 bar 90 psig 16 m³/h 9.4 cfm 100 ms ½" NB (12)
CPV-4 6.2 bar 90 psig 20 m³/h* 11.8 cfm* 100 ms ½" NB (12)
CPV-6 6.2 bar 90 psig 16 m³/h 9.4 cfm 100 ms ½" NB (12)
CPV-8 6.2 bar 90 psig 25 m³/h* 14.7 cfm* 100 ms ½" NB (12)
CPV-12 6.2 bar 90 psig 25 m³/h 14.7 cfm 100 ms ½" NB (12)
Collector type
Pulse
duration
Minimum
pipe
diameter
c
Working compressed
air pressure
a
Atmospheric air
volume – F.A.D. at
12 sec. intervals
b