Specifications
19
Installation, Operation and Maintenance Manual
PowerCore
®
Dust Collectors – Series CPV
SPECIFICATION
For other specifications on this product refer to Publication 3010.
For controller specifications refer to Publication 2699.
6.9 bar (100 psig)Design pressure:
Manifold volume:
Maximum operating
pressure, PS:
TABLE 2 – COMPRESSED AIR MANIFOLD DESIGN DETAILS
10.35 bar (150 psig)Test pressure:
−30° to +150°CDesign temperature:
Maximum rating of
pressure relief device:
25 dm³/s at 7.1 bar (factory set at 7.1 bar) (not supplied as standard)
7 litres (CPV-2)
12 litres (CPV-3 and CPV-6)
17 litres (CPV-4 and CPV-8)
27 litres (CPV-12)
Product of pressure
and capacity:
43.4 bar litres (CPV-2)
74.4 bar litres (CPV-3 and CPV-6)
105.4 bar litres (CPV-4 and CPV-8)
167.4 bar litres (CPV-12)
Structural hollow section
Material used for
manifold construction:
Minimum metal
thickness before
manifold requires
special inspection:
To improve corrosion resistance the manifold is painted externally and
internally using cathodic electrocoat.
5.5 mm
1 bar = 10
5
Pa
6.2 bar (90 psig)