7 Refit and tighten the hexagonal head set screws and shakeproof washers.
8 Push-fit 6 mm diameter nylon tube back into valve.
Annually
1 Moisture separator Isolate the compressed air supply; remove and clean
the filter element.
2 Air manifold Having isolated the compressed air supply, remove the drain
plug and air inlet connections and clean out any accumulated sludge and
inspect to any current local legislation.
It may be necessary to remove a diaphragm valve for internal
inspection purposes.
3 Doors Check the dust seals on all access doors for damage or ageing
and ensure that they are properly seated to prevent entry of water. This is
particularly important where the collector is located outside or in a wet
atmosphere.
Faulty seals must be replaced.
4 Antistatic earthing (if fitted) – Check collector earthing continuity.
5 Explosion risks – Check measures taken to avoid ignition sources are still
in place.
Figure 4 Valve diaphragm replacement
A
B
Diaphragm valve
Manifold