Technical data Coldmachine
36
Test/certificates:
The coolant circuit contains R-134a.
Contains fluorinated greenhouse gases
VD-16 for series 80 VD-16 for series 90
Max. cooling area
content at 35 mm PU
insulation:
120 litres 200 litres
Max. cooling area
content at 50 mm PU
insulation:
200 litres 250 litres
Power consumption: 65 W 80 W
Voltage 12 V g or 24 V g
Coolant quantity: 40 g
CO2 equivalent: 0.057 t
Global warming
potential (GWP):
1430
Dimensions
(WxHxD) in mm:
380x300x62
Weight: 5.0 kg
Coldmachine-IO-16s.book Seite 36 Mittwoch, 1. Mรคrz 2017 4:47 16