12 Troubleshooting
LED on the thermal element (fig. 1 2, page 3)
Number of
flashes
Error type Remedy
1 Battery protection shutdown Check battery voltage, fuse and cable
cross section
2 Fan overvoltage shutdown Check condenser and vaporiser fan
current:
total target value < 0.5 A
3 Compressor start-up fault Reduce load on cooling system:
Ensure good ventilation around the
cooling unit
Store pre-cooled goods
4 Compressor overload shutdown Reduce load on cooling system:
Ensure good ventilation around the
cooling unit
Store pre-cooled goods
5 Electronic fuse shutdown Reduce load on cooling system:
Ensure good ventilation around the
cooling unit
Coldmachine-IO-16s.book Seite 29 Mittwoch, 1. März 2017 4:47 16