User manual
11
PRODUCT DIMENSIONS
MODELS 5009, 5047,
5048, 5049
MODELS 5147,
5148, 5149
MODEL 5006
Toilet dimensions may vary ± 3/8-inch (10mm).
TROUBLESHOOTING GUIDE (cont’d)
Problem Possible Cause Service Instructions
15. Blockage between toilet and
vacuum generator.
16. Pump emits odor.
a. Collapsed vacuum line.
b. Sharp bends or kinks in vacuum
hose.
c. Improper operation of toilet.
d. Foreign objects were flushed
down toilet.
a. Loose or defective hose
connection on pump.
b. Loose intake or discharge
fittings on pump.
c. Worn, torn or punctured pump
bellows (vacuum generator) or
diaphragm (vacuum holding
tank).
a. Inspect vacuum line for
collapsed condition. Replace if
needed.
b. Inspect vacuum hose for kinks
or bends. If less than 8.5-inches
(216mm) radius on any bend,
reposition hose to achieve
minimum 8.5-inch bend radius.
c. Make sure each person using
toilet knows correct procedure.
d. DO NOT flush any non-dissolv-
ing items (i.e. sanitary napkins,
facial tissue, wet strength
tissue, paper towels, etc.) or
excessive toilet tissue down
toilet. Rapid-dissolving SeaLand
brand toilet tissue is best.
a. Tighten connections or
replace hose and make new
connections.
b. Tighten intake or discharge fit-
tings on pump. Replace nipples
or adapters if necessary.
c. Replace pump bellows or
diaphragm.