Installation Guide
EN
Preparing the installation SKL101, SKS101
10
5.2 Connecting the gas supply
The gas supply may only be installed by a tested and certified gas plumber.
!
I
➤ Observe the following:
– Use the opening at the rear of the slide out kitchen to route and service all
external plumbing and wiring.
– Connect the slide out kitchen to LPG only.
– Ensure that the connection to the gas supply is serviceable by the user. It must
require detachment before closing the slide out kitchen.
WARNING!
The female gas connection provided can only be connected to a rigid
connection. For use with a flexible hose, install a copper pipe to the base
plate of the slide out kitchen and fix it rigidly (fig. 7, page 10).
NOTE
•
For the gas connection the following additional parts are required:
– male gas adaptor
– copper piping
–pipe mount
– hose fitting
– flexible gas hose at required length, depending on the mounting
application
•
Make sure that the hose line
–is not crushed or kinked
– is a safe distance from the burner.
7
1
2
SKL101-I-AUS.book Seite 10 Donnerstag, 18. Oktober 2018 10:50 10