Installation Instructions

EN
Saneo B, Saneo C Installing the toilet
25
Performing a measurement to test the flushing output
For performing a measurement to test the flushing output, there are two
variants:
Variant 1:
➤ Disconnect the hose connection of the toilet from the vehicle line.
➤ Place the open end of the line into a bucket.
➤ Actuate the flushing for 1 minute using the toilet operating unit.
➤ Measure the volume of water in the bucket.
The volume of water that is in the bucket corresponds to the water flow
rate in l/min.
Variant 2:
➤ Disconnect the hose connection of the toilet from the vehicle line.
➤ Connect a Gardena water meter to the toilet water line.
➤ Actuate the flushing using the toilet operating unit.
➤ Read the water flow in l/min on the Gardena water meter.
With all Saneo models, the water connection is established as described
above.
Exception: Models Saneo xW with integrated water tank.
I
NOTE
Water supply (vehicle-side pump):
The toilet requires a min. of 7 l/min provided by the vehicle at
the outlet of the hose connection of the toilet in order to ensure
satisfactory flushing output of 5 l/min.