Installation Manual

EN
RUC5208X, RUC6408X, RUC8408X Connecting the refrigerator
23
8 Connecting the refrigerator
8.1 Connecting the refrigerator to 12 24 V
A
The refrigerator can be operated with a 12 V or 24 V DC voltage supply.
For safety reasons, the refrigerator is equipped with an electronic system to prevent
the polarity being reversed. This protects the refrigerator against reversed polarity
when connecting to a battery and against short circuiting.
To protect the battery, the refrigerator switches off automatically if the voltage is
insufficient (see table below).
Determine the required cross section of the cable in relation to the cable length
according to the figure above.
NOTICE!
To avoid voltage drops and loss of performance, keep the
connection cable as short as possible and uninterrupted.
Therefore avoid additional switches, plugs or power strips.
12 V 24 V
Cut-off voltage
10.4 V 22.8 V
Cut-in voltage
11.7 V 24.2 V
0
0
2
6
10
14
246810121416182022242628
24 V
l/m
Ø/mm²
12 V
j
RUC8408X--IO-AU.book Seite 23 Montag, 8. Juli 2019 1:56 13