Installing the refrigerator RUA5208X, RUA6408X, RUA8408X
16
➤ Shield the opening with a deflector to prevent sludge or dirt from getting inside
while driving (fig. b).
If you have to use a roof vent instead of an upper wall vent:
➤ Cut out a section in the roof. Refer to the roof vent instruction manual for the
required dimensions. When doing so, observe the information, see chapter “Pre-
paring the installation” on page 6.
6.4 Installing the drain water hose
➤ To avoid damage on the drain water hose, position the hole for the drain water
hose in a way, that the hose does not touch the boiler casing.
➤ Drill a hole through the floor at the rear of the refrigerator.
➤ Install the drain water hose through the drilled hole. Ensure, that the drain water
hose is long enough in order to drain the water outside of the vehicle.
➤ Ensure that the drain water hose is not kinked.
➤ Seal the area around the drain water hose.
6.5 Installing the ventilation grille
3
2
1
LS 300
c
DometicRUA5208X6408X8408X_INM_4445102444_APAC(en)_xxxx-xx-xx.book Seite 16 Dienstag, 1. Dezember 2020 5:16 17