Shield the opening with a deflector to prevent sludge or dirt from getting inside
while driving (fig. b).
If you have to use a roof vent instead of an upper wall vent:
Cut out a section in the roof. Refer to the roof vent instruction manual for the
required dimensions. When doing so, observe the information, see chapter “Pre-
paring the installation” on page 6.
6.4 Installing the drain water hose
To avoid damage on the drain water hose, position the hole for the drain water
hose in a way, that the hose does not touch the boiler casing.
Drill a hole through the floor at the rear of the refrigerator.
Install the drain water hose through the drilled hole. Ensure, that the drain water
hose is long enough in order to drain the water outside of the vehicle.
Ensure that the drain water hose is not kinked.
Seal the area around the drain water hose.
6.5 Installing the ventilation grille