Installation Manual

EN
RUA5208X, RUA6408X, RUA8408X Installing the refrigerator
11
The recommended maximum distance between the refrigerator and the rear wall
is 25 mm. A distance of more than 25 mm between the refrigerator and rear wall
leads to poor performance and increases the power consumption of the
refrigerator. Reduce the space behind the refrigerator to maximum 25 mm to
create adequate air inlet and outlet ventilation corridor (fig. 4 and fig. 5). Use
a ventilation plate, for example, to do this.
Installation with one lower side vent and one roof vent
Pos. in fig. 6 Description
1 Insulation wool on top and sides of cabinet
2 Clearance minimum 10mm to maximum 25mm
3 LS300 ventilation grille
4 Minimum height is equal to the height of the cabinet plus 150 mm
5 Dometic gas flue kit 3776
RUA 5208X RUA 6408X, RUA 8408X
5
6
3
4
1
2
5
6 6
3
4
1
2
7
7
6