Installation Guide

EN
Installing the refrigerator RUA6408X, RUA8408X
10
Installation with one lower side vent and one roof vent
If the minimum distance between the air inlet and outlet vents cannot be met, a
roof vent must be installed instead of the air outlet vent.
The roof vent should be installed directly above the back of the refrigerator as
far as this is possible. Use an air duct if you need to install the roof vent
(fig. 4 6) offset, otherwise heat will accumulate there.
Pos. in
fig. 2, page 8
Description
1 Insulation wool on top and sides of cabinet
2 Recommended maximum clearance 25 mm
3 LS300 vent
4 Minimum height is equal to the height of the cabinet plus 150 mm
5 Dometic gas flue kit 3776
6 Roof vent
5
3
4
1
6
2
4